AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 23 of 95<br />

13 OFF N/A (+): Off Time Increase for a No Arrival. Off Time is increased for every No Arrival until<br />

the Maximum Off Time is achieved. A higher time value is recommended (30 to 60 minutes) to<br />

ensure the well has enough time to respond and return to the proper plunger travel speed.<br />

15 INITIAL FAST: This counter is the initial setting for the Fast Window. It determines how many Fast<br />

Arrivals the well must make before allowing Afterflow to commence. The value will not change<br />

unless you modify the default setting.<br />

16 CURRENT FAST: This counter is the Current or Present count of plunger arrivals in the Fast<br />

Window. The Current Fast Counter is reduced each time the plunger arrives in the Fast<br />

Window. Once this counter reaches 0 the well is allowed to Afterflow. It will reset to the initial<br />

value for a No Arrival or the plunger arriving in the Slow Window.<br />

17 INITIAL GOOD: This counter is the initial setting for the Good Window. It determines how many<br />

Good Arrivals the well must make before allowing Afterflow to commence. The value will not<br />

change unless you modify the default setting.<br />

18 CURRENT GOOD: This counter is the Current or Present count of plunger arrivals in the Good<br />

Window. The Current Good Counter is reduced each time the plunger arrives in the Good<br />

Window. Once this counter reaches 0 the well is allowed to Afterflow. It will reset to the initial<br />

value for a No Arrival or the plunger arriving in the Slow Window.<br />

19 INITIAL SLOW: This counter is the initial setting for the Slow Window. It determines how many<br />

consecutive Slow Arrivals the well can make before shut-in occurs. The value will not change<br />

unless you modify the default setting.<br />

20 CURRENT SLOW: This counter is the Current or Present count of plunger arrivals in the Slow<br />

Window. The Current Slow Counter reduces each time the plunger arrives in the Slow Window.<br />

Once the present counter reaches 0 the well will shut-in. Any Fast or Good Arrival will<br />

automatically reset this counter to the Initial Slow value.<br />

21 INITIAL N/A: This counter is the initial setting for the No Arrival Window. It determines how<br />

many consecutive No Arrivals the well can make before shut-in occurs. The value will not<br />

change unless you modify the default setting.<br />