AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 23 of 95<br />
13 OFF N/A (+): Off Time Increase for a No Arrival. Off Time is increased for every No Arrival until<br />
the Maximum Off Time is achieved. A higher time value is recommended (30 to 60 minutes) to<br />
ensure the well has enough time to respond and return to the proper plunger travel speed.<br />
15 INITIAL FAST: This counter is the initial setting for the Fast Window. It determines how many Fast<br />
Arrivals the well must make before allowing Afterflow to commence. The value will not change<br />
unless you modify the default setting.<br />
16 CURRENT FAST: This counter is the Current or Present count of plunger arrivals in the Fast<br />
Window. The Current Fast Counter is reduced each time the plunger arrives in the Fast<br />
Window. Once this counter reaches 0 the well is allowed to Afterflow. It will reset to the initial<br />
value for a No Arrival or the plunger arriving in the Slow Window.<br />
17 INITIAL GOOD: This counter is the initial setting for the Good Window. It determines how many<br />
Good Arrivals the well must make before allowing Afterflow to commence. The value will not<br />
change unless you modify the default setting.<br />
18 CURRENT GOOD: This counter is the Current or Present count of plunger arrivals in the Good<br />
Window. The Current Good Counter is reduced each time the plunger arrives in the Good<br />
Window. Once this counter reaches 0 the well is allowed to Afterflow. It will reset to the initial<br />
value for a No Arrival or the plunger arriving in the Slow Window.<br />
19 INITIAL SLOW: This counter is the initial setting for the Slow Window. It determines how many<br />
consecutive Slow Arrivals the well can make before shut-in occurs. The value will not change<br />
unless you modify the default setting.<br />
20 CURRENT SLOW: This counter is the Current or Present count of plunger arrivals in the Slow<br />
Window. The Current Slow Counter reduces each time the plunger arrives in the Slow Window.<br />
Once the present counter reaches 0 the well will shut-in. Any Fast or Good Arrival will<br />
automatically reset this counter to the Initial Slow value.<br />
21 INITIAL N/A: This counter is the initial setting for the No Arrival Window. It determines how<br />
many consecutive No Arrivals the well can make before shut-in occurs. The value will not<br />
change unless you modify the default setting.<br />
2913 Specialty Drive • P.O. Box 130158 • Tyler, TX 75713-0158 • Phone: 903-561-4851 • Fax: 903-561-6567