AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 83 of 95<br />
10. Click on the Measurement tree and select the Current Values tab.<br />
11. Ensure the numerical identifier corresponds with Table 7.22. If not, write down the numerical identifiers for each<br />
item.<br />
12. From the Operate menu, select File Utilities and select Save and Restore Utility<br />
13. Expand the R: Tree and select Modbus.<br />
14. From the Operate menu, select File Utilities and select Modbus Slave Register Editor.<br />
15. Enter 7001 for Map Start and 6 for # Registers. Select Register List from the View menu.<br />
16. Using Table 7.22, fill in the register numbers.<br />
17. Select Send and enter an appropriate file name of your choice.<br />
18.<br />
19.<br />
20.<br />
Totalflow<br />
Register<br />
Description<br />
Modbus<br />
Register<br />
11.3.0 Static Pressure 7001<br />
11.7.0 Differential Pressure 7002<br />
11.3.3 Temperature 7003<br />
11.7.19 Flow Rate 7004<br />
11.7.22 Today’s Volume 7005<br />
11.7.23 Yesterday’s Volume 7006<br />
Table 7.22: Totalflow Modbus Register Map<br />
Press the Save Station Files button and select an appropriate file directory.<br />
Once the save is completed, answer Yes to restoring files to the S: drive.<br />
Click OK to complete the restore.<br />
Figure 7.32: Totalflow Save Station Files<br />
Figure 7.31: Totalflow Register Map<br />