There are three types of SMS commands that may be sent to the AC<strong>iC</strong>:<br />

Read-Only Commands: Read-Only commands are used to retrieve data that typically cannot be altered by the user.<br />

This type of information includes data points such as pressures, temperatures, and plunger run times among others.<br />

Retrieving information using a Read-Only command can be done by sending the Shortcut or Hotkey to the controller<br />

with no parameters.<br />

Step 1: User initiates read command<br />

SYS<br />

Step 2: ACIC generates the response<br />

Joe’s Mega Well<br />

BATT: 13.08V<br />

SOLAR: -1.0mA<br />

FW VER: 1.1.24.0<br />

PLG CTS: 21<br />

Read-Write Commands: Read-Write commands are used either to retrieve current values or change items in the AC<strong>iC</strong>.<br />

This type of command is used for changing settings such as control times or pressure overrides or retrieving the current<br />

setting. Retrieving a setting is done by sending the hotkey or shortcut with a preceding ‘?’ character. Altering a setting<br />

using Read-Write commands can be done by sending the Shortcut or Hotkey followed by a space character and a<br />

parameter.<br />

Step 1: User Initiates SMS<br />

?03 (request current ON time setting)<br />

Step 2: ACIC generates the response<br />

Joe’s Mega Well<br />

03 00:05:10<br />

Step 1: User Initiates SMS<br />

03 001010 (change ON time to 10 minutes and 10 seconds)<br />

Step 2: ACIC generates the response<br />

Joe’s Mega Well<br />

OLD 03 00:05:10<br />

NEW 03 00:10:10<br />

Write-Only Commands: Write-Only commands are used to explicitly modify the current behavior of the controller.<br />

These commands affect behavior such as enabling or disabling functionality, or closing valves. Write-Only commands<br />

are used without parameters by sending the Shortcut or Hotkey and will return only a confirmation once action is<br />

taken.<br />

Step 1: User Initiates SMS<br />

SHUTIN<br />

Step 2: remote ACIC generates the response<br />

Joe’s Mega Well<br />

SHUTIN Confirmed<br />