AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 34 of 95<br />
4.7.5 F5 <strong>–</strong> Overrides<br />
70 OPN IF CP >=: Open the Tubing Valve if the Casing Pressure is equal-to or greater-than the PSIG<br />
setting and the Minimum Off Time has expired.<br />
71 OPN IF TP >=: Open the Tubing Valve if the Tubing Pressure is equal-to or greater-than the PSIG<br />
setting. And the Minimum Off Time has expired.<br />
100 OPN IF TP-LP >: Open the Tubing Valve if the Tubing Pressure <strong>–</strong> Line Pressure is greater than the<br />
PSIG setting and the Minimum Off Time has expired.<br />
OPN IF TP-RMLP >: Open the Tubing Valve if the Tubing Pressure <strong>–</strong> Remote Line Pressure is<br />
greater than the PSIG setting and the Minimum Off Time has expired.<br />
101 OPN IF FSLUG >=: Open the Tubing Valve if the Fluid Slug setting is equal-to or greater-than the<br />
PSIG setting and the Minimum Off Time has expired.<br />
72 CLS IF CP