08.06.2013 Views

Operator's Manual – AutoCycle iC - Ferguson Beauregard

Operator's Manual – AutoCycle iC - Ferguson Beauregard

Operator's Manual – AutoCycle iC - Ferguson Beauregard

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 30 of 95<br />

PROPORTIONAL ADJ: Proportional Adjustments is a specific application that allows larger<br />

time adjustments as the arrival time deviates farther outside the Good Window. When a<br />

plunger arrival is in the Fast<br />

Window, more significant time<br />

adjustments may need to be<br />

made to decrease the Off Time<br />

and increase the Afterflow<br />

Time. Conversely, when a<br />

plunger arrival is in the Slow<br />

Window, more significant time<br />

adjustments may be needed to<br />

increase the Off Time and<br />

decrease the Afterflow Time.<br />

Figure 4.3: Depiction of Proportional Adjustments<br />

This is accomplished using a ‘ramp’ from the Fast Time to 50% of the Fast Window and a<br />

‘ramp’ from the Slow Time to 50% of the Slow Window. The minimum adjustment in<br />

either window is 25% of the adjustment setting. This is graphically shown in Figure 4.3.<br />

AUTO RESTART: This option allows the RTU to restart in the automatic mode after a power<br />

failure if the mode was automatic before the power failure.<br />

CP OFF AF ONLY: This option directs the RTU to honor Casing Pressure Off Overrides only<br />

during Afterflow if on (YES).<br />

TP OFF AF ONLY: This option directs the RTU to honor Tubing Pressure Off Overrides only<br />

during Afterflow if on (YES).<br />

DP OFF AF ONLY: This option directs the RTU to honor Differential Pressure Off Overrides<br />

only during Afterflow if on (YES).<br />

HL OFF AF ONLY: This option directs the RTU to honor High-Line Pressure Off Overrides<br />

only during Afterflow if on (YES).<br />

LO BATT CLS TB: This option directs the RTU to close the tubing valve when it detects a low<br />

battery before shutting down. Enabling this option will disable LO BATT OPN TBG.<br />

LO BATT OPN TBG: This option directs the RTU to open the tubing valve when it detects a<br />

low battery before shutting down. Enabling this option will disable LO BATT CLS TBG.<br />

2913 Specialty Drive • P.O. Box 130158 • Tyler, TX 75713-0158 • Phone: 903-561-4851 • Fax: 903-561-6567

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!