AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 55 of 95<br />

6.4 Parameters<br />

There are several parameter types to be used with Read-Write commands. The parameter associated with a<br />

Read-Write command will start as the first non-space character on a given line, not including the security code.<br />

Responses to Read-Write commands with required parameter value changes will also contain the well name and<br />

OLD and NEW values.<br />

Time: Time parameters are formatted hoursminutesseconds with no delimiters between each value and no leading<br />

zeroes. For example, 2000 represents 20 minutes 00 seconds while 100000 translates to 10 hours, 00 minutes, 00<br />

seconds. Confirmation messages containing times will use a colon (:).<br />

Integers: The ACIC supports up to 6 digit integers or whole numbers (123456).<br />

Floating Point: The ACIC supports up to 4 digits of precision floating point values (123456.0987)<br />

6.5 The Help Command<br />

The help command is a unique read-only command that accepts any other command as a parameter. When<br />

used, the AC<strong>iC</strong> will return a short description of the parameter command and its usage. Two question marks<br />

preceding any command type will initiate the help command. A maximum of two help commands can be sent<br />

per SMS message. No other command may be sent in the same SMS message as a help command.<br />

Step 1: User Initiates SMS<br />

?? SHUTIN<br />

?? 03<br />

Step 2: ACIC generates the response<br />

Joe’s Mega Well<br />

SHUTIN- Closes all valves, <strong>Manual</strong> Mode<br />

03 [hr:min:sec]-Current on time<br />

6.6 Unrecognized Commands<br />

Responses to unrecognized numerical and/or word based commands will be as follows:<br />

Step 1: User Initiates SMS<br />

SYSS<br />

Step 2: remote AC<strong>iC</strong> generates the response<br />

Joe’s Mega Well<br />

INV CMD: SYSS<br />