77 H-L DELAY: High Line Delay Time is a delay feature for use with a line pressure analog transducer.<br />
This delay time allows the normal cycle to make and break contact with this switch during the<br />
early part of the ON CYCLE and continue to operate. If the line pressure remains high and the<br />
contact is not broken before the delay times out, the well will shut in. This will automatically<br />
start the OFF TIME.<br />
78 OPN FST CP (-): Open if CP >= decrease adjustment for Fast Arrival.<br />
79 OPN SLW CP (+): Open if CP >= increase adjustment for Slow Arrival.<br />
80 OPN N/A CP (+): Open if CP >= increase adjustment for No Arrival.<br />
81 OPN FST TP (-): Open if TP >= decrease adjustment for Fast Arrival.<br />
82 OPN SLW TP (+): Open if TP >= increase adjustment for Slow Arrival.<br />
83 OPN N/A TP (+): Open if TP >= increase adjustment for No Arrival.<br />
84 CLS FST CP (-): Close if CP