AC<strong>iC</strong> Operator’s <strong>Manual</strong> Revision 4 Page 58 of 95<br />

6.11 SMS Command List<br />

6.11.1 Write Only Commands<br />

6.11.2 Read Only Commands<br />

Hotkey Shortcut Description Firmware<br />

Valve Control<br />

0000 SHUTIN Close all valves, force <strong>Manual</strong> Mode All<br />

6666 ON <strong>Manual</strong>ly Start On Cycle All<br />

7777 OFF <strong>Manual</strong>ly Start Off Cycle All<br />

Alarms and Schedules<br />

5678 ALARMON Enable Alarms for this phone number All<br />

2468 ALARMOFF Disable Alarms for this phone number All<br />

8888 SCHON Enable Schedule Delivery for this phone number All<br />

9999 SCHOFF Disable Schedule Delivery for this phone number All<br />

Server Controls<br />

4433 Change the server address or host name All<br />

2233 Change the server port number All<br />

8833 TCP Force the device to connect the server All<br />

Plunger Control<br />

56 Clear Plunger Totals All<br />

Table 6.1: Write Only Commands<br />

Hotkey Shortcut Description Firmware<br />

System Information<br />

60 VER Board and Firmware Revisions All<br />

5555 SYS Bat. & Solar Voltage, Firmware Rev., Plunger Counts All<br />

Analog Pressures<br />

501 Instantaneous Casing Pressure All<br />

502 Instantaneous Tubing Pressure All<br />

503 Instantaneous Line Pressure All<br />

3333 PRESS All Pressures (Instant, Min, Max, 24 Hr Average) All<br />

Plunger Control<br />

1111 SETTINGS Plunger Control Timer Settings and Arrival History All<br />

2222 TIMERS Current Running Timers All<br />

53 RT Last 10 Plunger Run Times All<br />

4444 ACIC Yesterday’s Accumulators (Cycles, Plunger Counts, On Time, Off Time, No Arrivals) All<br />

Flow Computer Information<br />

994 FCU Differential Pressure 1.2.0.2+<br />

995 FCU Line Pressure 1.2.0.2+<br />

996 FCU Line Temperature 1.2.0.2+<br />

997 Current Flow Rate 1.2.0.2+<br />

998 Yesterday’s Accumulated Volume 1.2.0.2+<br />

999 Today’s Accumulated Volume 1.2.0.2+<br />

9994 All FCU Information 1.2.0.2+<br />

Table 6.2: Read Only Commands<br />

2913 Specialty Drive • P.O. Box 130158 • Tyler, TX 75713-0158 • Phone: 903-561-4851 • Fax: 903-561-6567