2 <strong>Manual</strong> Operation and Setup<br />

2.4 3D Touch Probe Systems<br />

To calibrate the effective radius<br />

Position the ball tip in the bore hole of the ring gauge.<br />

TOUCH<br />

PROBE<br />

SURFACE = DATUM<br />

ENT<br />

CALIBRATION EFFECTIVE RADIUS<br />

X+ X– Y+ Y–<br />

RADIUS RING GAUGE = 0<br />

4 x<br />

5 ENT<br />

Displaying calibration values<br />

I<br />

Select the calibration function for the ball-tip radius.<br />

Select RADIUS RING GAUGE.<br />

Enter the radius of the ring gauge, here 5 mm.<br />

The effective length and radius of the 3D touch probe are stored in the<br />

<strong>TNC</strong> for use whenever the touch probe is needed again. The stored values<br />

are displayed the next time the calibration function is called.<br />

Fig. 2.10: Calibrating the touch probe radius<br />

The 3D touch probe contacts one position on the bore for each axis direction.<br />

<strong>TNC</strong> <strong>360</strong> 2-<strong>11</strong><br />

Z<br />

X<br />

10<br />

Y