2 <strong>Manual</strong> Operation and Setup<br />

2.5 Setting the Datum with the 3D Touch Probe System<br />

Corner as datum<br />

Select the CORNER = DATUM probe function.<br />

To use the points that just probed for a basic rotation:<br />

TOUCH POINTS OF BASIC ROTATION?<br />

e.g.<br />

0<br />

ENT<br />

or<br />

I<br />

I<br />

.<br />

.<br />

.<br />

ENT<br />

Fig. 2.14: Probing procedure for finding the coordinates of the<br />

corner P<br />

<strong>TNC</strong> <strong>360</strong> 2-15<br />

Y<br />

Y=?<br />

X=?<br />

Transfer the touch point coordinates to memory.<br />

Move the touch probe to a starting position near the first touch point on the side that was not probed for basic<br />

rotation.<br />

CORNER = DATUM<br />

X + X – Y + Y –<br />

Select the probing direction.<br />

Probe the workpiece.<br />

Move the touch probe to a starting position near the second touch point on the same side.<br />

DATUM X =<br />

Probe the workpiece.<br />

Enter the first coordinate of the datum point, here for the X axis.<br />

P<br />

X<br />

Y<br />

4<br />

3<br />

P<br />

1<br />

2<br />

X