Hiring of VPN Services for GAIL Agartala
Hiring of VPN Services for GAIL Agartala
Hiring of VPN Services for GAIL Agartala
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
provisions applicable <strong>for</strong> such installations from time to time. In<br />
case <strong>of</strong> power supply to CONTRACTOR's colony, the power<br />
will be made available at a single point and the CONTRACTOR<br />
shall make his own arrangement at his own cost <strong>for</strong> distribution<br />
to the occupants <strong>of</strong> the colony as per Electricity Rules and Acts.<br />
The site and colony shall be sufficiently illuminated to avoid<br />
accidents.<br />
2.4.7 The CONTRACTOR will have to provide and install his own<br />
lights and power meters which will be governed as per<br />
Central/State Government Electricity Rules. The metres shall be<br />
sealed by the EMPLOYER.<br />
2.4.8 In case <strong>of</strong> damage <strong>of</strong> any <strong>of</strong> the EMPLOYER’s equipment on<br />
account <strong>of</strong> fault, intentional or unintentional on the part <strong>of</strong> the<br />
CONTRACTOR, the EMPLOYER reserves the right to recover<br />
the cost <strong>of</strong> such damage from the CONTRACTOR's bill. Cost<br />
<strong>of</strong> HRC Fuses replaced at the EMPLOYER's terminals due to<br />
any fault in the CONTRACTOR's installation shall be to<br />
CONTRACTOR's account at the rates decided by the<br />
ENGINEER-IN-CHARGE.<br />
2.4.9 Only motors upto 3 HP will be allowed to be started direct on<br />
line. For motors above 3 HP and upto 100 HP a suitable<br />
Starting device approved by the ENGINEER- IN-CHARGE<br />
shall be provided by the CONTRACTOR. For motors above<br />
100 HP slipring induction motors with suitable starting devices<br />
as approved by the ENGINEER- IN-CHARGE shall be<br />
provided by the CONTRACTOR.<br />
2.4.10 The CONTRACTOR shall ensure at his cost that all electrical<br />
lines and equipment and all installations are approved by the<br />
State Electricity Inspector be<strong>for</strong>e power can be supplied to the<br />
EMPLOYER.<br />
2.4.11 The total requirement <strong>of</strong> power shall be indicated by the tenderer<br />
alongwith his tender.<br />
2.5 Land <strong>for</strong> Contractor’s Field Office, Godown and Workshop: The<br />
EMPLOYER will, at his own discretion and convenience and <strong>for</strong><br />
the duration <strong>of</strong> the execution <strong>of</strong> the work make available near the<br />
site, land <strong>for</strong> construction <strong>of</strong> CONTRACTOR's Temporary Field<br />
Office, godowns workshops and assembly yard required <strong>for</strong> the<br />
execution <strong>of</strong> the CONTRACT. The CONTRACTOR shall at his<br />
own cost construct all these temporary buildings and provide<br />
suitable water supply and sanitary arrangement and get the same<br />
approved by the ENGINEER-IN-CHARGE.<br />
On completion <strong>of</strong> the works undertaken by the CONTRACTOR,<br />
he shall remove all temporary works erected by him and have the<br />
SITE cleaned as directed by ENGINEER-IN-CHARGE. If the<br />
48