<strong>CE90WIN</strong>_<strong>EN</strong>_SP4<br />
Document Preview<br />
ADAPT00338514<br />
Description:<br />
Patch ID: 36690063<br />
With the (COM) DHTML viewer, when users select a letter for a parameter, the report is returned but the group tree only displays<br />
certain letters, or the “Unterminated string constant” web page error appears, and then the group tree fails to load.<br />
New Behavior:<br />
This problem is resolved.<br />
ADAPT00348525<br />
Description:<br />
Patch ID: 36812353<br />
Alert message boxes or current cookie information may be displayed accidentally when certain parameters are added to the end of a<br />
report URL being viewed in Crystal Enterprise. The cause of the problem is that script commands can be added to a report URL, and<br />
then executed.<br />
Two examples of such parameters are:<br />
1. &init=actxalert('XXS hole present');<br />
2. &promptex=alert(document.cookie);<br />
New Behavior:<br />
An error message is displayed when users execute any script as part of the report URL.<br />
ADAPT00358602<br />
Description:<br />
Patch ID: 36831778<br />
In some cases when the option "No Printer" is selected on the Printer Setup dialog box and a Crystal report is exported to MS Word,<br />
the page size on the exported file is set to "Custom size."<br />
New Behavior:<br />
This problem is resolved.<br />
General<br />
ADAPT00307997<br />
Description:<br />
Patch ID: 36915835<br />
Incorrect data type and size information is produced when users create a report in Crystal Reports that uses DB/C FS as a datasource,<br />
and then choose "Browse Data" to query available fields.<br />
New Behavior:<br />
This problem is resolved.<br />
General CMC Issues