<strong>CE90WIN</strong>_<strong>EN</strong>_SP1<br />
SDK<br />
ADAPT00140385<br />
Description:<br />
Patch ID: 35156292<br />
When users created a report against the tod32.dll (xfODBC) ODBC driver, a field of DATE type was brought in as a STRING type.<br />
New Behavior:<br />
A change has been made in the Crystal Reports ODBC driver that allows for the DATE type field to be returned properly when using<br />
the tod32.dll driver.<br />
ADAPT00144963<br />
Description:<br />
Patch ID: 35300620<br />
When reporting off a BIGINT field in a database, the following error messages appear, when using ODBC driver 3.0 or lower: "Failed<br />
to open a rowset."; "Query engine error - Driver does not support this parameter."; "Query engine error - Data is NULL, but no indicator<br />
variable supplied."<br />
New Behavior:<br />
If the ODBC driver in use is version 3.0 or lower, a BIGINT data type is correctly returned as a double.<br />
Security<br />
ADAPT00160709<br />
Description:<br />
Patch ID: 35345083<br />
When an LDAP group is mapped from Novell Directory Services, the following error is received: "Error updating LDAP properties: An<br />
internal error has occurred in the secLdap plugin."<br />
New Behavior:<br />
The problem is caused when a user account within the mapped LDAP group contains a trailing space in the account name. The LDAP<br />
security plug-in has been changed to account for that scenario.<br />
Server Discovery<br />
ADAPT00171794<br />
Description:<br />
Patch ID: 35418785<br />
After an FRS failover, occasionally, the Page Server would not detect the FRS. This problem occurred because there were multiple FRS<br />
entries in the Name Service when there should have only been one.<br />
New Behavior:<br />
NameServerSubsystem.dll was changed to prevent multiple FRS entries in the Name Service.<br />
Server functionality<br />
ADAPT00141193<br />
Description:<br />
Patch ID: 35153273<br />
If a user entered empty or null values for report parameter prompts, processing extensions would not be applied correctly on selection<br />
formulas.<br />
New Behavior:<br />
Processing extensions have been revised to incorporate the scenario of null values for report parameter prompts. After this change,<br />
processing extensions are applied correctly instead of being bypassed.