<strong>CE90WIN</strong>_<strong>EN</strong>_SP2<br />

General Desktop Issues<br />

ADAPT00096113<br />

Description:<br />

Patch ID: 34980990<br />

The Java viewer would recognize the null parameter value it received from the server, but it would return it as if it were an empty<br />

string. This problem only affected string parameters.<br />

New Behavior:<br />

Changes were made such that the promptex parameter value assignments are named and not numbered. If they are numbered, the<br />

Java viewer will assume that the print engine version is from a version that is prior to 8.0.<br />

Java Applet Viewer<br />

ADAPT00128662<br />

Description:<br />

Patch ID: 35036611<br />

When a report has several fonts with empty face names, the Java viewer throws an exception when it attempts to examine the<br />

non-existent first character of one of the face names.<br />

New Behavior:<br />

The Java viewer now checks the length of the face name before examining the first character. If the face name is empty, the viewer will<br />

not try to read it.<br />

Java SDK<br />

ADAPT00206274<br />

Description:<br />

Patch ID: 35694659<br />

When changing the data source location of a report using a RAS Java application, an RCAPI licensing error may occur.<br />

The problem is caused by RAS Java-library dependent files that were not properly updated in prior releases.<br />

New Behavior:<br />

The necessary Java-library dependent files are included in this patch, and the RCAPI error no longer occurs.<br />

Job Processing<br />

ADAPT00126208<br />

Description:<br />

Patch ID: 35467697<br />

When an attempt is made to schedule a report with a large number of embedded picklist values, the report would remain in a<br />

"Pending" status indefinitely.<br />

New Behavior:<br />

Under certain conditions, the Crystal APS would not load the processing information for these objects (with a large number of<br />

embedded picklist values) and, therefore, would not be able to process the report. A change has been made to always load this<br />

information for objects that are available to be processed.