15.3 Details of Load Module Converter Options<br />

15.3.3 Specifying to Output Start Address Record (-entry)<br />

When outputting the data the start segment address record or the start linear address<br />

record are output. This option can specify using f2hs only.<br />

■ Specifying to Output Start Address Record (-entry)<br />

[Format]<br />

-entry<br />

[Parameter]<br />

None<br />

[Description]<br />

Use this option to specify the start segment address record or the start linear address record are output.<br />

If there is no start address information in the input file, a warning will be output (W1504U: Start<br />

address information is not in an input file).<br />

To the Table 15.3-3 described below, the start address record is output according to specify output HEX<br />

format option (-I16/-I20/-I32) and the input data range.<br />

Table 15.3-3 The Start Address Records of HEX Format Output<br />

Specifying an<br />

Output HEX<br />

format<br />

input data range<br />

output start address record<br />

-I16 The warning 'W1503U: -entry option was<br />

specified at the time of -I16 specification' is<br />

displayed. The start address record does not<br />

output.<br />

-I20 0x<strong>00</strong><strong>00</strong><strong>00</strong><strong>00</strong>-0x<strong>00</strong>0FFFFF Start segment address record<br />

-I32 0x<strong>00</strong><strong>00</strong><strong>00</strong><strong>00</strong>-0x<strong>00</strong>0FFFFF Start segment address record<br />

0x<strong>00</strong>1<strong>00</strong><strong>00</strong>0-0xFFFFFFFF Start linear address record<br />

If Output HEX format is not specified, the data are processed as when the HEX32 format output option<br />

(-I32) is specified.<br />

[Example]<br />

f2hs ccp903.abs -entry -I16<br />

The warning 'W1503U: -entry option was specified at the time of -I16 specification' is displayed<br />

because -entry option specified when the HEX8 format output specification option (-I16) was specified.<br />

The start address record does not output.<br />

f2hs ccp903.abs -entry -I20<br />

The start segment address record output.<br />

f2hs ccp903.abs -entry -I32<br />

The start segment address record is output when the data address size is from 0x0 to 0xFFFFF.<br />

The start linear address record is output when the data address size is from 0x1<strong>00</strong><strong>00</strong>0 to 0xFFFFFFFF.<br />