15.3 Details of Load Module Converter Options<br />

15.3.5 Specifying to Adjust (-adjust)<br />

This option automatically calls the adjuster for adjustment after converting the load<br />

module.<br />

■ Specifying to Adjust (-adjust)<br />

[Format]<br />

-adjust<br />

[Parameter]<br />

None<br />

[Description]<br />

This option automatically calls the adjuster for adjustment after converting the load module.<br />

The starting/ending addresses to be adjusted are automatically set.<br />

If the starting/ending address parameters are specified with the padding (-p) option when this option is<br />

given, an error occurs.<br />

When this option is specified, the option for the adjuster can also be specified.<br />

[Example]<br />

f2ms ccp903 -p 0xEF,0x1FE4,0x1FFF -adjust<br />

Because the starting/ending addresses are specified with the padding option, an error occurs.<br />

f2ms ccp903 -p 0xEF -adjust<br />

This option converts the absolute format load module to an adjusted S format. In this case, it pads the<br />

location where no data exists with data named 0xEF.<br />