APPENDIX<br />

B.6 Extended Linear Address Record (HEX32) Type: 04<br />

If extended linear address record appears, the address of each byte data of the<br />

following data records is calculated according to the following formula.<br />

( ( PA x 0x1<strong>00</strong><strong>00</strong> ) + ( ( DA + DP ) MOD 0x1<strong>00</strong><strong>00</strong> ) ) MOD 0x1<strong>00</strong><strong>00</strong><strong>00</strong><strong>00</strong><br />

• PA: (e) field value of the record.<br />

• DA: (c) field value of the record. Here, this value is a relative address.<br />

• DP: Value indicating the data position in the (e) field of the data record calculated by<br />

setting the position of the first data to 0.<br />

■ Extended Linear Address Record (HEX32)<br />

Figure B.6-1 Extended Linear Address Record (HEX32)<br />

: 0 2 0 0 0 0 0 4 p1 p2 p3 p4 s1 s2<br />

(a) (b) (c) (d) (e) (f) (g)<br />

(e) :<br />

This is a paragraph address and the actual 2-byte data is represented as 4-byte ASCII code.<br />

In the above figure, p1 indicates the high-order digits.<br />

(c) :<br />

This field is not used and normally 0 is set.<br />

If extended linear address record appears, the address of each byte data of the following data records is<br />

calculated according to the following formula.<br />

[( PA x 0x1<strong>00</strong><strong>00</strong> ) + [( DA + DP ) MOD 0x1<strong>00</strong><strong>00</strong>]] MOD 0x1<strong>00</strong><strong>00</strong><strong>00</strong><strong>00</strong><br />

- PA: (e) field value of the record<br />

- DA: (c) field value of the record. Here, this value is a relative address.<br />

- DP: Value indicating the data position in the (e) field of the data record calculated by setting the<br />

position of the first data to 0.<br />

With the addition of extended linear address record, up to 32-bit addresses can be represented.<br />

For the data records which appear before the extended linear address record, the address is calculated with<br />

the above PA setting as 0x<strong>00</strong><strong>00</strong>.<br />