SYCON.net PROFIBUS DP Slave DTM
SYCON.net PROFIBUS DP Slave DTM
SYCON.net PROFIBUS DP Slave DTM
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Tools 93/132<br />
1. Open Packet Monitor.<br />
‣ Tools > Packet Monitor.<br />
2. Enter data for Packet header.<br />
Send > Packet header<br />
‣ Under Dest enter or select the receiver.<br />
‣ Under Cmd enter the read command identification.<br />
Sample Data<br />
Receiver 0x20 (Destination Que Handle)<br />
Read Command<br />
Identification<br />
00002F0C<br />
GET <strong>DP</strong>M IO INFO REQUEST<br />
(Request)<br />
Figure 62: Example - Reading data via „Get <strong>DP</strong>M IO Info“ – Send > Packet header<br />
Send > Send Data<br />
Figure 63: Example - Read data via „Get <strong>DP</strong>M IO Info“ - Send > Send Data<br />
Note: Entering send data is not required for the Get <strong>DP</strong>M I/O Information<br />
packet.<br />
<strong>DTM</strong> for Hilscher <strong>PROFIBUS</strong> <strong>DP</strong> <strong>Slave</strong> Device | Configuration of Hilscher <strong>Slave</strong> Devices<br />
DOC091001OI07EN | Revision 7 | English | 2011-09 | Released | Public © Hilscher, 2009-2011