Vacuum Gauges<br />
Bayard-Alpert Gauge<br />
Fieldbus<br />
Fieldbus allows processes or applications the flexibility and control of<br />
network communications. It permits communication of exact digital<br />
information, independent control, maintenance and diagnostic routines<br />
for each connected instrument and simplifies your connection diagram.<br />
Device type<br />
DeviceNet<br />
Explicit Peer to Peer Messaging<br />
I/O Peer to Peer Messaging<br />
BAG100-SD<br />
BAG101-SD<br />
generic<br />
no<br />
no<br />
The measures of control include: monitoring of measurement values,<br />
automatic zero point adjustment of gauges, update operator of scheduled<br />
maintenance work, warning signals in case of instrument failure, and more.<br />
Profibus DP<br />
The central automation systems, e.g. PLC/PC or process control systems,<br />
communicate through a fast serial connection with decentralized<br />
instruments such as I/O, motors, valves and pressure transducers.<br />
The exchange of data with the decentralized instruments takes place<br />
mostly in cycles. The basic functions of the Profibus DP Communication<br />
Profile also include acyclic communication services for parameter setting,<br />
controlling, monitoring, and alert functions of intelligent instruments.<br />
Configuration consistency value<br />
Faulted node recovery<br />
Baud rates<br />
Master/Scanner<br />
I/O Slave Messaging<br />
Bit Strobe<br />
Polling<br />
Cyclic<br />
Change of State (COS)<br />
Supply<br />
Connector<br />
k Baud<br />
V DC<br />
no<br />
no<br />
125<br />
250<br />
500<br />
no<br />
yes<br />
yes<br />
yes<br />
yes<br />
11 É 25<br />
Microstyle, 5 pin<br />
DeviceNet<br />
The DeviceNet interface supports polling, bit strobe and change of<br />
state/cyclic commands. Like with other DeviceNet instruments the user<br />
can monitor and control all available sensor functions.<br />
Profibus DP<br />
Supported baud rates (auto detection)<br />
k Baud<br />
BAG100-SP<br />
9.6<br />
19.2<br />
93.75<br />
187.5<br />
500<br />
1500<br />
Expanded user parameter data<br />
no<br />
Configuring<br />
Number of input and output data<br />
Bytes<br />
2 each<br />
Sync-Mode and Freeze-Mode<br />
yes<br />
Connector<br />
D sub, 9 pin<br />
mm (inches)<br />
B6.20