E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT<br />

Continuing Contract for Professional Services<br />

City of North Miami Beach<br />

(Complete one Section E for each key person.)<br />

12. Name 13. Role In This Contract 14. Years Experience<br />

W. Bruce Lafrenz, P.G. Hydrogeologist<br />

15. Firm Name And Location (City and State)<br />

<strong>Tetra</strong> <strong>Tech</strong>, Orlando, FL<br />

a. Total<br />

26<br />

b. With Current Firm<br />

15<br />

16. Education (Degree and Specialization) 17. Current Professional Registration (State and Discipline)<br />

B.S., University of Florida, 1981<br />

Professional Geologist, Florida, No. 1228<br />

M.S., University of Florida, 1986<br />

Professional Geologist, Georgia, No. 1411<br />

18. Other Professional Qualifications (Publications, Organizations, Training, Awards, etc.)<br />

Professional Affiliations: American Geophysical Union, American Institute of Professional Geologists/FAPG, American Water Resources<br />

Association, Geological Society of America, NGWA-Association of Groundwater Scientists and Engineers.<br />

19. Relevant Projects<br />

a.<br />

b.<br />

c.<br />

d.<br />

e.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Continuing Engineering Services, North Miami Beach, Florida<br />

Professional Services<br />

On-going<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member: Scope included preliminary design, final design, permitting, and construction services to expand plant capacity to treat a<br />

total of 32.0 MGD with nanofiltration and low pressure reverse osmosis technologies. The expanded facility consists of 15.0 MGD from existing<br />

lime softening facilities, 9.0 MGD for new nanofiltration facilities, 6.0 MGD from new low-pressure reverse osmosis facilities, and 2.0 MGD of<br />

micron filtered raw water blend. The existing facilities were also expanded and improved. Primary roles include groundwater modeling and<br />

water well design QA/QC review.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Continuing Water and Wastewater Consultant, Naples, Florida<br />

Professional Services<br />

On-going<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member for the Continuing Water and Wastewater Engineering Consulting Services for the City of Naples. Services to the City have<br />

included, permitting, water and wastewater system evaluations, Miscellaneous water main and wastewater collection system extensions, water<br />

and wastewater system operations, master planning, hydrogeological and water resources investigations, and financial management as it<br />

relates to the water and wastewater facilities. Primary roles include aquifer testing design and analysis, groundwater modeling, water use<br />

permitting, well design, and QA/QC review.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Continuing Consultant, Deltona, Florida<br />

Professional Services<br />

On-going<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member providing services for the Continuing Consultant contract for the City of Deltona. Services to the city have included support<br />

to several departments including Public Works, Public Utilities, Development Services, Parks and Recreation and the Building and Fire<br />

Department. Primary roles include aquifer testing and analysis, groundwater modeling, water use permitting, water well design, water resource<br />

exploration, and QA/QC review.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Continuing Engineering Services, James E. Anderson 22.5 MGD Reverse Osmosis Water<br />

Treatment Plant, Port St. Lucie, Florida<br />

Professional Services<br />

2008<br />

Construction (if applicable)<br />

2008<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member providing services for the ROWTP Expansion from 6.0 MGD ROWTP to 22.5 MGD including, design, permitting, and<br />

construction administration. <strong>Tetra</strong> <strong>Tech</strong> was the engineer of record for the original 6.0 MGD ROWTP and the subsequent expansion to 22.5<br />

MGD. The project included raw water supply, pipelines, membrane treatment, pre- and post-treatment, high service pumping, four 4 MG ground<br />

storage tanks, and concentrate disposal. Primary roles included groundwater modeling, water use permitting, and QA/QC review of well<br />

construction and testing data.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Toho Water Authority Pump Station No. 60 and 97 improvements, Kissimmee, Florida<br />

Professional Services Construction (if applicable)<br />

On-going<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member responsible for groundwater modeling, aquifer test analyses, and water use permitting. Participated in design, bidding, and<br />

summary report for five (5) public supply and exploratory test wells using the Lower Floridian aquifer as an alternative water source. Significant<br />

responsibility for QA/QC review of hydrogeological design, analysis, and reporting.<br />

SOLICITATION NO. 2012-10 E-1 FORM SF330 Part I<br />