E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT<br />

Continuing Contract for Professional Services<br />

City of North Miami Beach<br />

(Complete one Section E for each key person.)<br />

12. Name 13. Role In This Contract 14. Years Experience<br />

Felix W. Yao, P.E.<br />

15. Firm Name And Location (City and State)<br />

<strong>Tetra</strong> <strong>Tech</strong>, Orlando, FL<br />

Electrical Engineer (Electrical Instrumentation<br />

16. Education (Degree and Specialization) 17. Current Professional Registration (State and Discipline)<br />

B.S., Electrical Engineering, Kettering University, 2003 Professional Engineer, Florida, No. 6963<br />

18. Other Professional Qualifications (Publications, Organizations, Training, Awards, etc.)<br />

a. Total<br />

7<br />

b. With Current Firm<br />

5<br />

a.<br />

b.<br />

c.<br />

d.<br />

e.<br />

f.<br />

19. Relevant Projects<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Continuing Engineering Services, Alexander Orr Water Treatment Plant and South Miami-<br />

Dade Water Supply Systems, Miami, Florida<br />

Professional Services<br />

On-going<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member for the Alexander Orr, Jr. Water Treatment Plant Continuing Services. This project provides engineering services to<br />

evaluate and rehabilitate or replace process equipment. Other key projects include the lime kiln mechanical and electrical upgrades study, a<br />

process optimization study and a secondary settlement basin bypass study.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Toho Water Authority Pump Station No. 60 and 97 improvements, Kissimmee, Florida<br />

Professional Services<br />

2010<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Key Team Member providing professional engineering services to the Toho Water Authority. Projects have included numerous lift station<br />

upgrades and refurbishments, pipelines and other engineering services.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Eustis Wastewater Treatment Plant, Lake County, Florida<br />

Professional Services<br />

2010<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Project Engineer for the design of the power distribution system and interior and exterior lighting. Also replaced the existing control system<br />

which was based on a combination of CompactLogix PLCs and MicroLogix PLCs.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

South Florida Water Management District G-370 & G-372 Pump Stations, Clewiston, Florida<br />

Professional Services<br />

2010<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Electrical Engineer. Designed the control system upgrades to be capable of manually operating the pump station if all the local and remote<br />

automation failed to avoid catastrophic flooding in the area.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

OUC Eastern Water Treatment Facility Orlando, Florida<br />

Professional Services<br />

2010<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Designed the 4160V parallel emergency standby generators, neutral grounding resistors, 4160V power distribution system, and control system,<br />

for the expansion of the plant from 50MGD to 62.5MGD. Coordinated power feed with utility provider.<br />

(1) Title and Location (City and State) (2) Year Completed<br />

Poinciana Wastewater Treatment Plant #2, Toho Water Authority, Kissimmee, Florida<br />

Professional Services<br />

2007<br />

Construction (if applicable)<br />

(3) Brief Description (Brief scope, size, cost, etc.) and Specific Role Check if project performed with current firms<br />

Project Engineer for electrical and instrumentation for the upgrade and expansion of the Poinciana WRF #2. The WRF treatment capacity will<br />

be increased from 3.0 to 6.0 MGD. Project also includes abandoning the SBR process in favor of the Modified Ludzing Ettinger (MLE) process,<br />

new filtration facilities, modifications to the influent screens, a new grit removal system, odor control for the screening and grit removal<br />

operations, a new chlorine contact basin with transfer pumps, new effluent storage and pumping, new residuals handling, and associated<br />

electrical and instrumentation.<br />

SOLICITATION NO. 2012-10 E-1 FORM SF330 Part I<br />

Page 28