GL900 USER'S MANUAL
GL900 USER'S MANUAL
GL900 USER'S MANUAL
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Settings and Measurement<br />
About Level and Edge Operations<br />
In the level operation, the trigger conditions are assumed to be met only if they are met when the<br />
START key is pressed (after the timer reaches the set time).<br />
In the edge operation, the trigger conditions are assumed NOT to be met even if they are met when<br />
the START key is pressed (after the timer reaches the set time).<br />
The trigger conditions are assumed to be met only if they are no longer met and then are met again.<br />
Example) If the mode is Rising<br />
Trigger generation area<br />
The START key is pressed here.<br />
Measurement immediately<br />
starts in the level operation.<br />
An edge that<br />
exceeds the<br />
setting level<br />
is needed.<br />
Measurement starts here<br />
in the edge operation.<br />
Setting level<br />
About the Trigger and Alarm Operations<br />
H : A trigger/alarm is generated when the signal input rises to (or<br />
exceeds) the specified level.<br />
Trigger (alarm) generated area<br />
Measurement starts (alarm generated)<br />
Set level<br />
CH.1<br />
L<br />
: A trigger/alarm is generated when the signal input falls to (or falls below) the<br />
specified level.<br />
Trigger (alarm) generated area<br />
Measurement starts (alarm generated)<br />
Set level<br />
CH.1<br />
Win In<br />
: Used to specify the upper and lower limits for each channel. When the signal<br />
level goes within (or is within) either limit, a trigger/alarm is generated.<br />
Trigger (alarm) generated area<br />
Measurement starts (alarm generated)<br />
Set upper level<br />
Set lower level<br />
CH.1<br />
Win Out : Used to specify the upper and lower limits for each channel. When the signal<br />
level goes outside (or is outside) either limit, a trigger/alarm is generated.<br />
Trigger (alarm) generated area<br />
Measurement starts (alarm generated)<br />
Set upper level<br />
Set lower level<br />
CH.1<br />