<strong>GE863</strong>-<strong>QUAD</strong> / <strong>PY</strong> <strong>Software</strong> <strong>User</strong> <strong>Guide</strong><br />

1vv0300746 Rev. 1 - 23/10/06<br />

3.2.4.7 Unbarring all the Calls<br />

• Send command AT+CLCK=AB,0,<br />

where:<br />

is the network password required to change facility status<br />

• wait for response:<br />

Response Reason Action<br />

OK Barring is now disabled all calls will be allowed<br />

(unbarred)<br />

ERROR some error occurred Enable the extended error<br />

codes report (see par.2.5.2.1)<br />

and retry.<br />

+CME ERROR: 4<br />

operation not supported, the Check command syntax<br />

service required is not available<br />

+CME ERROR: 30 no network service Check for registration (see par.<br />

2.5.3.1) and signal strength.<br />

+CME ERROR: 16 wrong network password check network password and<br />

retry<br />

For example:<br />

1- Let's assume you want to disable all the barring services you might have previously activated and<br />

the network password of your operator is 0000:<br />

command:<br />

AT+CLCK=AB,0,0000<br />

response:<br />

OK<br />