14.01.2015 Views

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A25<br />

A RAPID METHOD FOR MEASURING ANTI-DEPRESSANTS IN POSTMORTEM BLOOD<br />

USING DUAL COLUMN LIQUID CHROMATOGRAPHY MASS SPECTROMETRY<br />

Jason H. Sklerov' <br />

Office <strong>of</strong> the Armed Forces Medical Examiner, Division <strong>of</strong> <strong>Forensic</strong> Toxicology, Armed Forces Institute <strong>of</strong> <br />

Pathology, Rockville, MD, U.S.A. <br />

A dual column, liquid chromatography mass spectrometry method was developed for the analysis <strong>of</strong> eleven<br />

anti-depressants and metabolites in 200uL <strong>of</strong> postmortem blood. Sample preparation consisted <strong>of</strong> internal<br />

standard addition, protein precipitation, and micr<strong>of</strong>iltration. Filtrates were injected onto an extraction<br />

column (Oasis® HLB, 20 x 2.1mm, dp=25um) and washed with deionized water, 20% acetonitrile, at<br />

3mLlmin. The trapped analytes were backflushed through a 10-port switching valve onto an analytical<br />

column (Zorbax® SB-CI8, 30 x 2.1mm, dp=3.5um) using a gradient <strong>of</strong> acetonitrile (20-80%) and 0.1%<br />

formic acid at a flow rate <strong>of</strong> O.5mLlmin. The positive, pseudomolecular ions <strong>of</strong> imipramine, desipramine,<br />

amitriptyline, nortriptyline, fluoxetine, paroxetine, fluvoxamine, trimipramine, N-desmethyl-trimipramine,<br />

clomipramine, and N-desmethyl-clomipramine were monitored following electrospray ionization. Overall<br />

instrumental analysis time was 11 minutes per sample including extraction and detection. Sample<br />

carryover, assessed by area% <strong>of</strong> signals in blank injections, was < 1.4% by the use <strong>of</strong> both a needle wash<br />

phase and injector programming. Linear ranges varied within a 0.025-lmg/L range and the online<br />

extraction recovery was between 75-105%. Additional time savings could be gained by the direct injection<br />

<strong>of</strong> diluted plasma, however, due to the inconsistencies in sample collection and the potential for signal<br />

suppression, a protein precipitation step was adopted for this work.<br />

Keywords: Anti-depressants, Dual-column, LC/MS<br />

r--­<br />

Page 139

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!