14.01.2015 Views

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SOFT 2004 Meeting Abstracts - Society of Forensic Toxicologists

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A56 <br />

AUTOMATED SOLID PHASE EXTRACTION PROCEDURE FOR THE SIMULTANEOUS<br />

ANALYSIS OF DELTA-9-TETRAHYDROCANNABINOL (THC), ll-HYDROXY-DELTA-9­<br />

TETRAHYDROCANNABINOL (11-0H-THC), AND Il-NOR-DELTA-9-TETRAHYDRO­<br />

CANNABINOL-9-CARBOXYLIC ACID (THCC) IN BLOOD, PLASMA, AND ORAL FLUID BY<br />

GCIMSIMS<br />

Paul J. Davis*' \ Nadine Koenigl, Joann Sell I and Dean F. Fritch2, lHealth Network Laboratories, 2024<br />

Lehigh Street, Allentown, PA, 20raSure Technologies, Inc., 150 Webster Street, Bethlehem, PA<br />

A forensic automated procedure for the quantitative determination <strong>of</strong> THC, II-OH-THC, and THCC in<br />

whole blood, plasma, and oral fluid by GCIMS/MS is presented. Samples are treated with acetonitrile,<br />

acidified with dilute acid, and all three analytes are simultaneously extracted by solid phase extraction<br />

using the Caliper Life Sciences Zymark RapidTrace® Solid Phase Extraction Workstation with Varian<br />

SPEC® C-IS SPE cartridges. The RapidTrace® conditioned the SPE cartridges with methanol, added the<br />

sample, washed the cartridges with water/methanol, dried the cartridges with nitrogen, and then eluted the<br />

three cannabinoids with hexane/ethyl acetate. The final extracts were evaporated, derivatized with BSTFA<br />

with 1% TMCS, and analyzed by GCIMSIMS using the Varian 1200 Quadrupole GCIMSIMS System.<br />

Quantitation was accomplished using THC-d3 and THCC-d3 as internal standards. Two product ions were<br />

chosen for each analyte with one product ion serving as the qualifier ion. Retention time had to be within<br />

I% and the ion ratio <strong>of</strong> the qualifier product ion within 20% for identification <strong>of</strong> the analytes. The limit <strong>of</strong><br />

quantitation (LOQ) for THC and II-OH-THC is I ng/mL while the LOQ for THCC is 5 ng/mL. The limit<br />

<strong>of</strong> detection (LOD) for THC and II-OH-THC is 0.5 ng/mL, and 2.5 ng/mL for THCC. Both THC and 11­<br />

OH-THC are linear to at least 40 ng/mL While THCC is linear to at least 200 ng/mL. The recovery <strong>of</strong> all<br />

three analytes was approximately 50% for all three specimen types tested. At the LOQ for all three<br />

analytes, between-run precision resulted in a relative standard deviation <strong>of</strong>less then 12%.<br />

Key words: THC, Automated, GCIMS/MS<br />

Page 170

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!