A31 <br />

ANALYSIS OF TETRAHYDROCANNABINOL (THC) AND CARBOXY·<br />

TETRAHYDROCANNABINOL (CTHC) IN WHOLE BLOOD<br />

Amy Kinkennon*, Tim Robert, David Black, Peter Stout<br />

Aegis Sciences Corporation, Nashville, TN, USA<br />

THC and CTHC were isolated from I mL <strong>of</strong> whole blood using SPEWare Cerex PolyChrom THC SPE<br />

cartridges (35 mg beds). Analytes were eluted, and then derivatized with PFPA. Samples were<br />

reconstituted in 50 ul <strong>of</strong> ethyl acetate, and 2 uL injected on an HP 5890 GC interfaced to a Finnigan TSQ<br />

7000 MSIMS.<br />

The MSIMS was used in the positive CI mode for THC, and negative CI mode for the CTHC, with methane<br />

as the reagent gas. The THC molecular ion at 461 mlz was selected in Ql, collided with Ar in Q2, and two<br />

daughter ions monitored in Q3. The CTHC did not generate a strong molecular ion (622 m/z), so a 602 m/z<br />

fragment was selected in Q L This fragment was collided with Ar in Q2, and two daughter ions monitored<br />

in Q3. D3·THC and D3-CTHC were used as internal standards, and appropriate ions were monitored for<br />

these compounds. Analysis time was -15 min per sample.<br />

The method was shown to have a linear range <strong>of</strong> I-50 nglml for THC and 5-50 ng/ml for CTHC. Precision<br />

and accuracy studies were conducted using known control materials manufactured in drug free blood with<br />

good accuracy and precision over the linear range. Interference studies indicated that neither ibupr<strong>of</strong>en<br />

(110 uglml), acetaminophen (110 ug/ml), salicylate (700 uglml), nor ethanol (63 uglml) affected the<br />

analysis. Forty authentic blood samples from previous casework were analyzed using this method. Twenty<br />

had screened positive, and had been confirmed by an outside laboratory. Nine had screened positive, were<br />

sent for confirmation, and were returned negative. Eleven had screened negative and had not been<br />

previously confirmed.<br />

Keywords: Blood analysis, Carboxy-THC, Tandem mass spectrometry<br />