WARNING: Installation, usage, and maintenance of this product<br />
must be in compliance with all Engineered Controls International,<br />
Inc. instructions as well as requirements and provisions of NFPA<br />
#54, NFPA #58, DOT, ANSI, all applicable federal, state, provincial<br />
and local standards, codes, regulations, and laws.<br />
Inspection and maintenance on a periodic basis is essential.<br />
Installation and maintenance should be performed only by qualified<br />
personnel.<br />
Be sure all instructions are read and understood before<br />
installation, operation and maintenance. These instructions must be<br />
passed along to the end user of the product.<br />
CAUTION: Contact or inhalation of liquid propane, ammonia and<br />
their vapors can cause serious injury or death! NH 3 and LP-Gas<br />
must be released outdoors in air currents that will insure dispersion<br />
to prevent exposure to people and livestock. LP-Gas must be kept<br />
far enough from any open flame or other source of ignition to prevent<br />
fire or explosion! LP-Gas is heavier than air and will not disperse or<br />
evaporate rapidly if released in still air!<br />
INSTALLATION<br />
1) The Hose End Adapter is easily installed on to the end of a liquid<br />
fill hose by simply fastening the outlet of the hose into the Adapter<br />
inlet fitting (see figure) and securing with sufficient torque to prevent<br />
leakage.<br />
2) Pressurize the adapter and check for leaks around all fittings<br />
including the quick disconnect yoke.<br />
3) Properly adjust the adapter so that the yoke arm fits securely<br />
behind the wrenching section of the 7141M check connector. Use<br />
the lock nut to secure the adjusting screw in position.<br />
7193K-10B LEVER OPERATED<br />
HOSE END ADAPTER FOR<br />
FORKLIFT CYLINDER FILLING<br />
INSTALLATION AND OPERATION<br />
OPERATION<br />
1. Verify that the operating handle is in the up position.<br />
2. Position the adapter so that the yoke arm is behind the<br />
wrenching section of the 7141M-check connector.<br />
3. Move the operating handle to the down position. The quick<br />
disconnect yoke should move into the 7141M check connector<br />
smoothly. If done properly, this connection should not leak.*<br />
4. Open the service valve on the cylinder. Gas will now pass into<br />
the cylinder.<br />
5. Once the filling operation is complete, close the service valve on<br />
the cylinder.<br />
6. Move the operating handle back to the up position and<br />
disconnect the adapter from the check connector.<br />
NOTE: There may be a small amount of gas released at the time<br />
the adapter is disconnected from the check connector.<br />
7. Inspect the check connector for leaks and verify that all gaskets<br />
and o-rings are intact before placing the cylinder back into<br />
service.<br />
*This adapter is ideally suited to fit the 7141M-check connector.<br />
The use of this adapter with other check connectors may result in<br />
an ineffective seal. Some adjustment may be necessary when connecting<br />
to different manufacturers check connectors because of<br />
dimensional differences in the connectors themselves.<br />
Adjusting Screw<br />
Locknut<br />
Adapter Inlet Fitting<br />
Quick Disconnect Yoke<br />
Yoke Arm<br />
Operating Handle (Shown in down position)