WARNING: Installation, usage and maintenance of this product<br />

must be in compliance with all Engineered Controls International,<br />

Inc. instructions as well as requirements and provisions of NFPA<br />

#54, NFPA #58, DOT, ANSI, all applicable federal, state, provincial<br />

and local standards, codes, regulations and laws.<br />

Inspection and maintenance on a periodic basis is essential.<br />

Installation and maintenance should be performed only by qualified<br />

personnel.<br />

Be sure all instructions are read and understood before installation,<br />

operation and maintenance. These instructions must be<br />

passed along to the end user of the product.<br />

CAUTION: Contact or inhalation of liquid propane, ammonia and<br />

their vapors can cause serious injury or death! NH3 and LP-Gas<br />

must be released outdoors in air currents that will insure dispersion<br />

to prevent exposure to people and livestock. LP-Gas must be kept<br />

far enough from any open flame or other source of ignition to<br />

prevent fire or explosion! LP-Gas is heavier than air and will not<br />

disperse or evaporate rapidly if released in still air!<br />

The 7609-50 contains 20 feet of cable for connecting an emergency<br />

shut-off valve to the downstream loading hose. Cable-to-hose<br />

straps and a stainless steel clamp are provided to secure the cable<br />

end to the hose.<br />

NOTE: The thermal-element to operate the emergency valves<br />

should be not more than 5 feet from the nearest end of the hose.<br />

Installation<br />

See figure below<br />

1. Make a loop connection with end of cable to the latching arm or<br />

valve pull lanyard using a loop sleeve contained in this kit.<br />

7609-50 Transfer Hose<br />

Cable Kit<br />

Installation Instructions<br />

2. Run cable parallel to piping up to a point where the cable can now<br />

be angled towards the nearest end of the hose. A guide such as an<br />

eye bolt, or a single sheave pulley will be required to change the<br />

direction of the cable.<br />

3. Clamp cable with a nylon-bundle-tie to the hose immediately next<br />

to fixed piping or swivel type connection. From this point back to the<br />

valve, the cable should be taut but not strained. To avoid accidental<br />

tripping of the valve, this section of cable run must not be strained<br />

by normal handling of the loading hose.<br />

4. Continue clamping cable to hose with ties approximately every 12".<br />

Allow a minimum of 1 /2" of cable slack between ties. The cable need<br />

only be clamped to half the length of the hose.<br />

5. Terminate the cable by securing it with the stainless steel hose<br />

clamp 12" from the last nylon tie. Before the hose clamp is tightened,<br />

slip the cable through the clamp and make a loop sleeve. Be sure<br />

to allow 1 /2" of cable slack before tightening hose clamp.<br />

6. With the valve latched open, move the hose to simulate the normal<br />

movement of the hose during usage. The valve should not trip. Also,<br />

check to see if the stainless steel hose clamp has slipped, and if so,<br />

re-adjust and tighten. Note: The only time that the cable will trip the<br />

valve closed is when a truck accidently pulls the hose and causes<br />

the hose to stretch.<br />

Extend Emergency Cable To<br />

50% Of Total Hose Length<br />

5' 0" Max.<br />

* Nylon Cable Bundle Ties<br />

1<br />

/2" per foot cable slack<br />

* Stainless Steel<br />

Hose Clamp<br />

(This End Only)<br />

Fuseable Link<br />

Guide Pulley<br />

1' 0" Typ.<br />

Loading Hose<br />

ToTruck<br />

* Loop Sleeve Splice<br />

* 1 /16" Diameter Stainless Steel Cable (7 x 7 Strand)<br />

Liquid<br />

Or<br />

Vapor<br />

Emergency Valves<br />

Bulkhead<br />

* Provided in 7609 Cable Kit

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!