WARNING: Installation, usage and maintenance of this product<br />

must be in compliance with all Engineered Controls International,<br />

Inc. instructions as well as requirements and provisions of NFPA<br />

#54, NFPA #58, DOT, ANSI, all applicable federal, state, provincial<br />

and local standards, codes, regulations and laws.<br />

Inspection and maintenance on a periodic basis is essential.<br />

Installation and maintenance should be performed only by<br />

qualified personnel.<br />

Be sure all instructions are read and understood before<br />

installation, operation and maintenance. These instructions<br />

must be passed along to the end user of the product.<br />

CAUTION: Contact or inhalation of liquid propane, ammonia<br />

and their vapors can cause serious injury or death! NH3 and<br />

LP-Gas must be released outdoors in air currents that will<br />

insure dispersion to prevent exposure to people and livestock.<br />

LP-Gas must be kept far enough from any open flame or other<br />

source of ignition to prevent fire or explosion! LP-Gas is heavier<br />

than air and will not disperse or evaporate rapidly if released<br />

in still air!<br />

Installation<br />

1. Connect gas line to the inlet of 7193R-10 Quick Connect POL<br />

Fill Adapter. Pressurize Fill Adapter and open the quick acting<br />

valve. Check for leaks using a suitable leak detection solution.<br />

2. Adjust clamp to allow easy movement on and off cylinder valves.<br />

Use the double nuts to secure clamp in position. For compact<br />

cylinder valves, a distance of 1 /8" to 1 /4" between the clamp and<br />

the end of the tailpiece will usually allow satisfactory operation.<br />

7193R-10 Quick Connect<br />

POL Fill Adapter<br />

Operation and Installation<br />

Operation<br />

With the Quick Acting Valve open:<br />

1. Move the lever arm approximately 90° from the body of the Fill<br />

Adapter.<br />

2. Place the tailpiece into the female POL opening on the cylinder<br />

valve. The clamp should be placed on the upper body of the<br />

cylinder valve -- just above the relief section.<br />

3. Return the lever arm against the body of the Fill Adapter.<br />

4. Open service valve on the cylinder. The gas will now pass into<br />

the cylinder.<br />

5. Once the filling operation is complete, close the service valve on<br />

the cylinder.<br />

6. Move the lever arm approximately 90° away from the Fill Adapter<br />

body. This moves the clamp away from the upper body and<br />

places the tailpiece back into the closed position.<br />

Note: There will be a slight pop as the tailpiece moves away from<br />

the female POL and releases the trapped gas between the seat and<br />

service valve. Caution: If gas continues to discharge, close the<br />

quick acting valve immediately. Remove the Fill Adapter from<br />

service and repair.<br />

7. Remove the Fill Adapter from the cylinder valve.<br />

POL Opening<br />

on Cylinder Valve<br />

Clamp<br />

Tailpiece<br />

Quick Acting Valve<br />

(shown in the<br />

“vertical” open position)<br />

7193R-10<br />

Quick Connect POL<br />

Fill Adapter<br />

Double Nuts<br />

Gas Line<br />

Lever Arm