FS g3 m a1 a2 a3 a4 nL nH d1…dk<br />

[Function]<br />

[Code]<br />

Writing data into <strong>the</strong> download user NV memory<br />

HHHHHHHH<br />

HH[]nL+(nH × 256)<br />

[Range] m=0<br />

6000H (a1+(a2 × 256)+(a3 × 65536)+(a4 × 16777216)) 7FFFH<br />

Sto rage start address (nL+(nH × 256)) 1024<br />

k=(nL+(nH × 256))<br />

[Outline]<br />

This command loads data into <strong>the</strong> download user NV memory.<br />

• “m” is fixed at 0.<br />

• a1, a2, a3, a4 set <strong>the</strong> data storage start address at (a1+(a2 ×<br />

256)+(a3 × 65536)+(a4 × 16777216)).<br />

• nL, nH sets <strong>the</strong> number <strong>of</strong> stored data to (nL+(nH × 256)) bytes.<br />

• “d” denotes <strong>the</strong> data to be stored.<br />

[Details]<br />

• The download user NV memory refers to a storage area<br />

exclusively for character data secured on non-volatile memory.<br />

Font A:Start address 6000H End address 71FFH (36 bytes for<br />

1 character)<br />

Font B: Start address 7200H End address 7F7FH (27 bytes for<br />

1 character)<br />

• When <strong>the</strong> STANDARD MODE is selected, this command is valid<br />

only when it is written at <strong>the</strong> head <strong>of</strong> <strong>the</strong> line.<br />

• This command is invalid when PAGE MODE is selected.<br />

• If this command is sent while a macro is being defined, <strong>the</strong><br />

definition process will be stopped and <strong>the</strong> execution <strong>of</strong> this<br />

command will start.<br />

• If <strong>the</strong> argument (m), <strong>the</strong> storage start address (a1, a2, a3, a4),<br />

or <strong>the</strong> number <strong>of</strong> stored data (nL, nH) is outside <strong>the</strong> definition<br />

area, this command becomes invalid and <strong>the</strong> following data<br />

will be processed as normal data.<br />

• Date storage processing causes “overwriting” to be executed,<br />

thus erasing <strong>the</strong> data stored already before <strong>the</strong> storage<br />

processing was executed.<br />

• When an error occurs during <strong>the</strong> writing process, <strong>the</strong> error<br />

will be a “Memory or gate-array R/W error”.<br />

• Data in <strong>the</strong> user NV memory can be read by using <strong>the</strong> FS g4<br />

command.<br />

• Data in <strong>the</strong> user NV memory is not initialized by using <strong>the</strong> ESC<br />

@ command, <strong>the</strong> FS q command or by resetting <strong>the</strong> <strong>printer</strong> or<br />

turning <strong>the</strong> <strong>power</strong> <strong><strong>of</strong>f</strong>.<br />