[Caution]<br />
[Reference]<br />
• When <strong>the</strong> XON/XOFF control is selected, all <strong>the</strong> codes are sent<br />
continuously without verifying that <strong>the</strong> host can receive <strong>the</strong><br />
data. Data that has been sent is always continuous except for<br />
<strong>the</strong> XOFF code.<br />
• When parallel interface is used, <strong>the</strong> size <strong>of</strong> <strong>the</strong> buffer for<br />
sending data (The buffer that stores all data to be sent except<br />
for ASB status) is 99 bytes. Data which exceeds 99 bytes, will<br />
be discarded.<br />
• Data can be written into <strong>the</strong> download user NV memory using<br />
<strong>the</strong> FS g3 command.<br />
• There may be a delay between receiving this command and<br />
storing <strong>the</strong> data depending on <strong>the</strong> state <strong>of</strong> <strong>the</strong> receiving buffer.<br />
• After <strong>the</strong> header is sent, all data will be sent without verifying<br />
whe<strong>the</strong>r <strong>the</strong> host can receive <strong>the</strong> data or not. Therefore, <strong>the</strong><br />
available space in <strong>the</strong> receiving buffer <strong>of</strong> <strong>the</strong> host should be<br />
more than (The number <strong>of</strong> sent data+2) in order not to lose<br />
data during <strong>the</strong> execution <strong>of</strong> this command.<br />
• While data is being sent, real time commands (Commands<br />
with a DLE extension) will be ignored. And even if <strong>the</strong> ASB<br />
function is validly selected, ASB status will not be sent while<br />
data is in <strong>the</strong> process <strong>of</strong> being sent. Therefore, it is not possible<br />
to check <strong>the</strong> change in <strong>the</strong> <strong>printer</strong> state by checking its status.<br />
The user must pay attention to this.<br />