BD2 <strong>System</strong> — <strong>160</strong> ... 1250 A<br />
© Siemens AG 2007<br />
Junction units<br />
With aluminum busbars<br />
Version<br />
Length/<br />
Optional length<br />
L-units (with clamp terminal),<br />
with engineered angle 85° ... 175°<br />
(fitted to Y as standard)<br />
Knee, rear<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y<br />
Y0.36 ... 1.25<br />
85˚ – 75˚<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X<br />
NSV0_00436<br />
DT Rated current I e<br />
<strong>160</strong> A, 250 A, 315 A, <strong>40</strong>0 A<br />
PS*<br />
Type Order No. kg<br />
Weight<br />
per unit<br />
approx.<br />
X BD2A-<strong>40</strong>0-LH-G* BVP:261858 1 unit 8.000<br />
X BD2A-<strong>40</strong>0-LH-X*-G* BVP:261859 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LH-Y*-G* BVP:261860 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LH-X*/Y*-G* BVP:261861 1 unit 28.000<br />
Knee, front<br />
85˚ – 175˚<br />
Y<br />
X<br />
NSV0_00437<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X BD2A-<strong>40</strong>0-LV-G* BVP:261862 1 unit 8.000<br />
X BD2A-<strong>40</strong>0-LV-X*-G* BVP:261863 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LV-Y*-G* BVP:261864 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LV-X*/Y*-G* BVP:261865 1 unit 28.000<br />
Elbow, right<br />
Y<br />
Elbow, left<br />
Y<br />
X<br />
85˚ – 175˚<br />
NSV0_00438<br />
X<br />
85˚-175˚<br />
NSV0_00439<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
Elbow: For G* you must specify the required number of degrees<br />
in 5° increments.<br />
Optional lengths: For X* and Y* you must specify the required<br />
dimension in meters from the center of the clamp terminal to the<br />
outside edge of the trunking unit (see also page 5/81).<br />
Special colors available on request<br />
X BD2A-<strong>40</strong>0-LR-G* BVP:261866 1 unit 8.000<br />
X BD2A-<strong>40</strong>0-LR-X*-G* BVP:261867 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LR-Y*-G* BVP:261868 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LR-X*/Y*-G* BVP:261869 1 unit 28.000<br />
X BD2A-<strong>40</strong>0-LL-G* BVP:261870 1 unit 8.000<br />
X BD2A-<strong>40</strong>0-LL-X*-G* BVP:261871 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LL-Y*-G* BVP:261872 1 unit 18.000<br />
X BD2A-<strong>40</strong>0-LL-X*/Y*-G* BVP:261873 1 unit 28.000<br />
5<br />
Version Type suffix Order No. PS* Weight<br />
per unit<br />
approx.<br />
kg<br />
Fire barriers for L-units (optional)<br />
Fire barriers S90 in X dimension X +BD2-S90-BX*-M* BVP:931956 1 unit 1.000<br />
Fire barriers S90 in Y dimension X +BD2-S90-BY*-M* BVP:931957 1 unit 1.000<br />
Fire barriers S120 in X dimension X +BD2-S120-BX*-M* BVP:931959 1 unit 1.500<br />
Fire barriers S120 in Y dimension X +BD2-S120-BY*-M* BVP:931960 1 unit 1.500<br />
For BX* or BY you must specify the required dimension in meters<br />
from the center of the clamp terminal (for BX*: end without clamp<br />
terminal) to the center of the fire wall or fire ceiling, for M* specify<br />
the wall or ceiling thickness.<br />
For configuring of the fire barrier see page 5/94.<br />
5/34 Siemens LV 70 · 2006<br />
* You can order this quantity or a multiple thereof.