© Siemens AG 2007<br />

<strong>BD01</strong> <strong>System</strong> — <strong>40</strong> ... <strong>160</strong> A<br />

Introduction<br />

■ Benefits<br />

7 Flexible power supply<br />

7 Easy and quick planning<br />

7 Time-saving mounting<br />

7 Reliable mechanical and electrical connection<br />

7 High stability, low weight<br />

7 Few basic modules required<br />

7 Storage-friendly system<br />

7 Variable changes of direction<br />

7 Versatile tap-off units<br />

7 Positive opening and closing of tap-off points<br />

7 Accessories for increasing the degree of protection to IP55 for<br />

extreme environmental conditions<br />

■ Design<br />

Trunking units<br />

Connections<br />

NSV0_00045<br />

Assembly of the trunking units, also with end flanges and feeder<br />

units, is fast and inherently secure. The trunking unit or end<br />

flange is simply inserted in the lower housing of the clamp terminal.<br />

Once the upper part of the clamp terminal or feeder unit is<br />

fitted, a secure connection is established by tightening four<br />

screws. The PE path is established automatically when the<br />

enclosures are connected.<br />

An expansion compensation mechanism is built into the clamp<br />

terminal.<br />

End flanges<br />

NSV0_00042<br />

Trunking units are available in 2 m and 3 m lengths. They consist<br />

of a galvanized metal enclosure with a light gray (RAL 7035) aluminum<br />

painted finish. They are equipped with 4 busbars for L1,<br />

L2, L3 and N (aluminum conductors; copper for <strong>160</strong> A; silverplated<br />

copper pick-up and connection contacts).<br />

The enclosure of the trunking unit also serves as PE conductor.<br />

Five current ratings are available in only one frame size: <strong>40</strong> A,<br />

63 A, 100 A, 125 A and <strong>160</strong> A.<br />

The tap-off points are spaced at regular intervals of 0.5 m or 1 m<br />

on one side. The 2 m lengths have two or four tap-off points, the<br />

3 m lengths three or six.<br />

The end flanges provide protection against direct contact at the<br />

ends of the busbar run. They are suitable for use with all<br />

systems. Two end flanges are supplied as standard with each<br />

feeder unit.<br />

Junction units<br />

4<br />

L1<br />

L2<br />

L3<br />

N<br />

PE<br />

NSV0_00043<br />

The tap-off points are finger-safe. They are opened automatically<br />

by the tap-off units and close by themselves when the<br />

tap-off units are removed.<br />

The junction units, which consist of flexible conductors, are<br />

available in versions for 100 A and <strong>160</strong> A, each in 0.5 m and 1 m<br />

lengths.<br />

The flexible junction units enable the direction of the busbar run<br />

to be changed as required. The 0.5 m version is recommended<br />

for right angles, the 1 m version for fitting around obstacles or for<br />

adapting to variations in height.<br />