© Siemens AG 2007<br />

<strong>BD01</strong> <strong>System</strong> — <strong>40</strong> ... <strong>160</strong> A<br />

Tap-off units and ancillary equipment units<br />

for Denmark<br />

■ Selection and ordering data<br />

Version Rated current Rated operational<br />

voltage<br />

Tap-off units, aluminum, size 1<br />

With 1-pole fuse base D01 and<br />

with 2 socket outlets 10 A<br />

DT Type Order No. PS* Weight<br />

per unit<br />

approx.<br />

A V kg<br />

13 230 X <strong>BD01</strong>-AK1X/<br />

2DKS103S14<br />

BVP:203099 1 unit 1.<strong>40</strong>0<br />

With 1-pole miniature circuit-breaker 13 A,<br />

characteristic C, and with 2 socket outlets 10 A<br />

13 230 X <strong>BD01</strong>-AK1X/<br />

2DKS103A131<br />

BVP:203100 1 unit 1.500<br />

Tap-off units, aluminum, size 2<br />

With 2 × 1-pole fuse base D01,<br />

with 4 socket outlets 10 A<br />

13 230 X <strong>BD01</strong>-AK2X/<br />

4DKS103S14<br />

BVP:203102 1 unit 2.000<br />

With 2 × 1-pole miniature circuit-breaker 13 A,<br />

characteristic C, and with 4 socket outlets 10 A<br />

13 230 X <strong>BD01</strong>-AK2X/<br />

4DKS103A131<br />

BVP:203103 1 unit 2.200<br />

Tap-off units, aluminum, size 2, with mounting unit<br />

With 1-pole miniature circuit-breaker 13 A, characteristic C,<br />

with 2-pole RCCB 16 A/30 mA and<br />

with 2 socket outlets 10 A<br />

13 230 X <strong>BD01</strong>-AK2M1/<br />

2DKS103FIA131<br />

BVP:203101 1 unit 2.000<br />

4<br />

Ancillary equipment units, aluminum, size 1<br />

P v max. 13 W,<br />

with 4 socket outlets 10 A<br />

– <strong>40</strong>0 X <strong>BD01</strong>-GK1X/4DKS103 BVP:203104 1 unit 1.200<br />

Ancillary equipment units, aluminum, size 2<br />

P v max. 16 W,<br />

with 2 socket outlets 10 A and 1 CEE socket outlet, 16 A,<br />

5-pole<br />

– <strong>40</strong>0 X <strong>BD01</strong>-GK2X/<br />

2DKS103CEE165<br />

BVP:203105 1 unit 1.600<br />

NSV0_00264<br />

NSV0_00261<br />

NSV0_00257<br />

NSV0_00255<br />

NSV0_00255<br />

NSV0_00250<br />

NSV0_00250<br />

Gauge ring/gauge screw, fuse links and screw cap not<br />

included as standard with tap-off units.<br />

M50 cable grommets and screws for connecting the enclosure<br />

are included as standard with ancillary equipment units.<br />

Use plastic cable glands with strain relief (not included as<br />

standard)<br />

* You can order this quantity or a multiple thereof.<br />

Siemens LV 70 · 2006<br />