12.03.2015 Views

BD01 System – 40 ... 160 A - GRUP DAP

BD01 System – 40 ... 160 A - GRUP DAP

BD01 System – 40 ... 160 A - GRUP DAP

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>BD01</strong> <strong>System</strong> — <strong>40</strong> ... <strong>160</strong> A<br />

© Siemens AG 2007<br />

Tap-off units and ancillary equipment units for<br />

Belgium<br />

■ Selection and ordering data<br />

Version Rated current Rated operational<br />

voltage<br />

DT Type Order No. PS* Weight<br />

per unit<br />

approx.<br />

A V kg<br />

Tap-off units, aluminum, size 1<br />

With 2-pole miniature circuit-breaker 16 A, characteristic C<br />

• With 2 socket outlets 16 A 16 230 X <strong>BD01</strong>-AK1X/<br />

2PC163A162<br />

BVP:203115 1 unit 1.620<br />

• With 1 CEE socket outlet, 16 A, 3-pole 16 230 X <strong>BD01</strong>-AK1X/<br />

CEE163A162<br />

BVP:203114 1 unit 1.620<br />

Tap-off units, aluminum, size 1, with mounting unit<br />

4<br />

With 1-pole miniature circuit-breaker 16 A,<br />

characteristic C<br />

With 2-pole miniature circuit-breaker 16 A,<br />

characteristic C<br />

With 3-pole miniature circuit-breaker 16 A,<br />

characteristic C<br />

With 3-pole and N-pole miniature circuit-breaker 16 A,<br />

characteristic C<br />

With 1-pole miniature circuit-breaker 20 A,<br />

characteristic C<br />

With 2-pole miniature circuit-breaker 20 A,<br />

characteristic C<br />

With 3-pole miniature circuit-breaker 20 A,<br />

characteristic C<br />

With 3-pole and N-pole miniature circuit-breaker 20 A,<br />

characteristic C<br />

Tap-off units, aluminum, size 2<br />

With 2 × 2-pole miniature circuit-breaker 16 A,<br />

characteristic C,<br />

with 4 socket outlets 16 A<br />

16 230 X <strong>BD01</strong>-AK1M1/A161/1 BVP:203106 1 unit 1.600<br />

16 230 X <strong>BD01</strong>-AK1M1/A162 BVP:203110 1 unit 1.720<br />

16 <strong>40</strong>0 X <strong>BD01</strong>-AK1M1/A163 BVP:203107 1 unit 1.850<br />

16 <strong>40</strong>0 X <strong>BD01</strong>-AK1M1/A163N BVP:203111 1 unit 1.970<br />

20 230 X <strong>BD01</strong>-AK1M1/A201 BVP:203108 1 unit 1.600<br />

20 230 X <strong>BD01</strong>-AK1M1/A202 BVP:203112 1 unit 1.720<br />

20 <strong>40</strong>0 X <strong>BD01</strong>-AK1M1/A203 BVP:203109 1 unit 1.850<br />

20 <strong>40</strong>0 X <strong>BD01</strong>-AK1M1/A203N BVP:203113 1 unit 1.970<br />

16 230 X <strong>BD01</strong>-AK2X/<br />

4PC163A162<br />

BVP:203116 1 unit 2.320<br />

Ancillary equipment units, aluminum, size 1<br />

P v max. 13 W,<br />

with 4 socket outlets 16 A<br />

– <strong>40</strong>0 X <strong>BD01</strong>-GK1X/4PC163 BVP:203117 1 unit 1.200<br />

NSV0_00261<br />

NSV0_00255<br />

NSV0_00252<br />

NSV0_00251<br />

NSV0_00250<br />

M50 cable grommets and screws for connecting the enclosure<br />

are included as standard with ancillary equipment units.<br />

Use plastic cable glands with strain relief (not included as<br />

standard)<br />

4/20 Siemens LV 70 · 2006<br />

* You can order this quantity or a multiple thereof.