28.04.2015 Views

AT Commands Set

AT Commands Set

AT Commands Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SIM5215_SIM5216 <strong>AT</strong> Command Manual<br />

Defined values<br />

, <br />

RLP version number in integer format, and it can be 0, 1 or 2; when version indication is not<br />

present it shall equal 1.<br />

<br />

IWF to MS window size.<br />

<br />

MS to IWF window size.<br />

<br />

Acknowledgement timer.<br />

<br />

Retransmission attempts.<br />

<br />

Re-sequencing period in integer format.<br />

NOTE and are in units of 10 ms.<br />

Examples<br />

<strong>AT</strong>+CRLP?<br />

+CRLP:61,61,48,6,0<br />

+CRLP:61,61,48,6,1<br />

+CRLP:240,240,52,6,2<br />

OK<br />

4.15 <strong>AT</strong>+CR Service reporting control<br />

Description<br />

Write command controls whether or not intermediate result code “+CR: ” is returned from<br />

the TA to the TE. If enabled, the intermediate result code is transmitted at the point during connect<br />

negotiation at which the TA has determined which speed and quality of service will be used, before<br />

any error control or data compression reports are transmitted, and before the intermediate result<br />

code CONNECT is transmitted.<br />

SIM PIN References<br />

YES 3GPP TS 27.007<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>+CR=?<br />

Read Command<br />

Responses<br />

+CR: (list of supported s)<br />

OK<br />

Responses<br />

SIM5215_SIM5216_<strong>AT</strong> Command Manual_V1.13 44<br />

1/13/2011

Hooray! Your file is uploaded and ready to be published.