6. DISTRESS OPERATIONS<br />

2. Press the [7] key ([6] key when the <strong>FELCOM</strong> <strong>15</strong> functions as an EGC<br />

receiver) to display the Test menu.<br />

Test<br />

1. PV Test<br />

2. PV Test Result<br />

3. Self Test<br />

4. Distress Alert Button Test<br />

3. Press the [4] key.<br />

Test menu<br />

Options<br />

1. Login Test<br />

2. 1. Logout PV Test Distress Alert Button Test Start<br />

3. 2. Abort PV Test Result<br />

4. 3. Select Self Test NCS<br />

Yes No<br />

5. 4. Ocean Distress Region Alarm Button Test<br />

6. Test<br />

Distress alert button mode screen<br />

4. Press the [Enter] key to start the test. The buzzer sounds repeatedly,<br />

signifying the start of the test mode. Further, the message “Distress buttons<br />

are under test. Cancel the test mode if a real distress alert needs to sent.” is<br />

displayed in red.<br />

Options<br />

1. Login Test<br />

2. 1. Logout PV Test Distress Alert Button Test<br />

3. 2. Abort PV Test Result<br />

4. 3. Select Self Test NCSDistress alert button test mode.<br />

5. 4. Ocean Distress Region Alarm Press Button any key Test CAUTION to escape.<br />

INF: Distress 6. Test Buttons entered into TEST MODE.<br />

<br />

Distress alert button test<br />

5. Open the [DISTRESS] button cover.<br />

6. Press the [DISTRESS] button four seconds. The buzzer sounds rapidly for<br />

three seconds and then sounds repeatedly, as in step 4. The message<br />

“Distress Button works correctly.” appears if the button is working properly.<br />

7. Close the [DISTRESS] button cover.<br />

8. To escape from the test, press the [Esc] key on the keyboard of the terminal<br />

unit twice. The test mode alarm stops and the message shown below<br />

appears to notifying you that normal operation has been restored.<br />

CAUTION<br />

INF: Distress Buttons returned to NORMAL OPERATION.<br />

<br />

Distress buttons returned to normal state<br />

9. Press the [Esc] key three times to return to the standby display.<br />

6-6