Chapter 4 <br />

Note:<br />

The S0 Interface Module is also compatible with Alcatel Reflexes sets<br />

Figure 4.60: Example of Configuration with an S0 Interface Module<br />

The S0 module provides an S0 bus supplying power. An external power supply (230V AC/48V<br />

DC adapter) is required.<br />

There are two possible operating modes on the S0 bus:<br />

- Non permanent layer: layer 1 must be set up by the calling end (PCX or terminal) at the<br />

start of each call; layer 1 is shut down at the end of the call<br />

- Permanent layer: operation of the S0 bus depends on the direction in which the initial call<br />

was set up:<br />

• If the call was set up from the PCX to the terminal, layer 1 is kept when the call ends.<br />

• If the call was set up from the terminal to the PCX, layer 1 is shut down at the end of<br />

the call. It must be set up again for the following call. If operation is incompatible with<br />

the terminal used, there are two possible solutions: Either layer 2 is kept, this prevents<br />

layer 1 being shut down, or, layer 1 is set up from the PCX by making a call to the<br />

terminal. The call does not need to get through.<br />

4.9.1.2 Compliant Standards<br />

4.9.1.2.1 Safety Requirements<br />

4.9.1.2.2 ECM<br />

- EN60950: European requirements<br />

- UL 1950: US requirements<br />

- CAN/CSA-C22.2 No 950-95: Canada<br />

4-86