from your body. When holding a board, always wear a grounding device such as a grounded wrist<br />

strap, and do not touch board components that are sensitive to static charge.<br />

Before attempting board installation/exchange, note the following system rules concerning the<br />

detection of boards:<br />

- A detected board is considered to be PRESENT<br />

- A PRESENT board can be ACCEPTED or REFUSED, depending on the system<br />

dimensioning criteria<br />

- On a cold reset, all PRESENT boards are taken into account (irrespective of whether they<br />

are ACCEPTED or REFUSED)<br />

- A board which is PRESENT on a cold reset can later be determined as ABSENT on a<br />

warm reset if in the meantime the board has been unplugged or there has been a board<br />

detection failure<br />

- After a cold or warm reset, new boards are always taken into account and declared as<br />

PRESENT (and then ACCEPTED or REFUSED)<br />

The following table describes situations more specifically relevant to plugging/unplugging<br />

boards.<br />

Situation<br />

A board is plugged into a slot never before<br />

occupied<br />

A board is replaced with another board of<br />

the same type<br />

A board is replaced with another board of a<br />

different type<br />

A PRESENT and ACCEPTED board is unplugged<br />

A PRESENT and REFUSED board is unplugged<br />

7.1.1.5.1 Adding a board into a vacant slot<br />

Description<br />

The board is detected as PRESENT and then<br />

determined to be ACCEPTED or REFUSED<br />

(according to configuration criteria, such as authorized<br />

positions and maximum hardware capacity).<br />

If the board is accepted, its accesses are<br />

taken into account depending on the system dimensioning<br />

criteria.<br />

As above, except when the replacement board is<br />

plugged in, configuration data for the previous<br />

board is cleared.<br />

The board's disappearance is detected and the<br />

board is considered as out of order and then AB-<br />

SENT. However, configuration data associated<br />

with the unplugged board remains available.<br />

The board's disappearance is detected and the<br />

board is considered as ABSENT. However, configuration<br />

data associated with the unplugged<br />

board remains available.<br />

The procedure presented below assumes that a board is to be installed in a vacant slot in the<br />

system cabinet.<br />

Note 1:<br />

Hot installation is forbidden in OmniPCX Office RCE Compact platforms. It is also forbidden for<br />

PowerCPU boards in all platforms.<br />

1. If a hot installation is not possible, stop the system and disconnect it from the mains power<br />

supply.<br />

7-3