4.2.1.5 Connection to the Public Network<br />

4.2.1.5.1 Digital Public Network via T0 Access (or DLT0 Private Network)<br />

The Alcatel-Lucent OmniPCX Office Communication Server system can be installed near the<br />

digital network termination or at a certain distance (up to 350 m), as required.<br />

Connection without T0/S0 Forwarding<br />

Caution:<br />

In T0 Point-to-Point installations, the Alcatel-Lucent OmniPCX Office Communication Server<br />

system MUST BE the terminating element of the bus and any other terminating resistor MUST BE<br />

removed.<br />

Connection with T0/S0 Forwarding<br />

In the event of a loss of tension or PowerCPU malfunction, the ISDN-EFM box allows a T0<br />

access to be forwarded directly to a S0 station.<br />

Caution:<br />

The AFU-1 board (daughter board of the PowerCPU board) must obligatorily be fitted to detect the<br />

absence of power.<br />