4.2.1.7.7 Using the 12V Output<br />

The GROUND and + 12V outputs on the AUX connector allow for the connection of an<br />

external 12V device with a maximum energy consumption of 150 mA (OmniPCX Office RCE<br />

Small and OmniPCX Office RCE Medium) or 300 mA (OmniPCX Office RCE Large).<br />

4.3 Power Supply<br />

4.3.1 <strong>Installation</strong> procedure<br />

4.3.1.1 Connecting an External EPS48 Power Supply<br />

The UAI16-1 board can optionally be powered by an external EPS48 power supply depending<br />

on the requirements for remotely powering the terminals.<br />

The mains socket for the external EPS48 power supply must be installed as near as possible<br />

to the system and be easily accessible.<br />

Caution:<br />

Only use the recommended power supply provided. It is guaranteed to operate at 40#C for a<br />

current load of 0.85A. Its use is limited to UAI16-1 boards.<br />

The power supply lead is used as the master switch. The power supply socket<br />

must be located or installed close to the hardware and allow easy access.<br />

The power supply cord is used as the main disconnect device, ensure that the<br />

socket-outlet is installed near the equipment and is easily accessible.<br />

4.3.1.2 Battery Implementation<br />

Alcatel-Lucent OmniPCX Office Communication Server is supplied with one or more integrated<br />

batteries; they are mounted and fixed with a solid bar on the rear plate.<br />

Caution:<br />

OmniPCX Office RCE Compact does not have integrated batteries.<br />

4.3.1.2.1 Battery Switch<br />

The batteries are disconnected during transport using a switch soldered onto the power supply<br />

board. When the mains cable is inserted in the socket, the switch is closed by a lever<br />

incorporated in the mains socket.<br />

4.3.1.2.2 Battery Fuse<br />

The battery fuse is located on the board and requires the back panel to be dismantled to gain<br />

access. It has the following characteristics:<br />

- OmniPCX Office RCE Small and OmniPCX Office RCE Large: 6.3 A fast, low cutoff (F 6.3<br />

AL/250 V).<br />

- OmniPCX Office RCE Medium: 10 A fast, low cutoff (F 10 AL/250 V)<br />

4.3.1.2.3 Battery Replacement<br />