3.6 VIEWING PROGRAM AND CONTROLLER PARAMETERS<br />

In Base Mode (i.e. with no profile currently running or held), pressing the<br />

SCROLL key will cause the instrument to display various information. The<br />

operator may view and change the setpoint, view the units the instrument is<br />

using, weather the outputs are on or off, the alarm status, the present time<br />

and day (if the real time clock is fitted), and the percent output of the control<br />

instrument if operating in Manual Mode.<br />

NOTE: If the SCROLL key is held for longer than two seconds, the instrument<br />

will automatically scroll through the displays.<br />

BASE<br />

MODE<br />

SETPOINT (Units) AlSt OUTPUTS time Day<br />

3.7 ADJUSTING THE CONTROLLER SETPOINT<br />

With the Setpoint Programmer in Base Mode (i.e. with the RUN, HLD, SET,<br />

MAN and PRG indicators OFF), the two main displays will show the process<br />

variable value (upper display) and the setpoint value (lower display -<br />

Read Only). To change the setpoint value:<br />

1. Press the SCROLL key, the Message Area will display:<br />

2. If Setpoint has been enabled in the Enable mode, use the UP and<br />

DOWN keys to change the setpoint value (in the lower display) as required.<br />

3. When the setpoint value is set as desired, press the SCROLL key<br />

again to view other Base mode parameters.<br />

Edition 1<br />

27 MIC 1462 Manual