3.11 SUMMARY<br />
SETTING UP <strong>ECOPROBE</strong> 5 BEFORE STARTING TO MEASURE<br />
Now we are at the end of the paramete<strong>rs</strong> of the Configuration File. Store the locality by selecting the option<br />
Save configuration at the end of the Configuration File (or use the left arrow and follow the instructions on the<br />
screen) to return to the Main Menu (Window W. 9.1).<br />
If you entered the Configuration File using the option Open<br />
LOCALITY 1 (see Window W 4) the new locality (ABC) is<br />
linked with LOCALITY 1. The name of this locality will be<br />
displayed after the option LOCALITY 1 in the Main Menu.<br />
If you entered the Configuration File using the option Open<br />
LOCALITY 2, the new locality is linked with LOCALITY 2.<br />
The name of the locality will be displayed after the option<br />
LOCALITY 2 in the Main Menu. In this way you can link<br />
one locality with LOCALITY 1 and one locality with<br />
LOCALITY 2. LOCALITY 1 and LOCALITY 2 directly open<br />
measuring modes of the localities. By selecting either<br />
LOCALITY 1 or LOCALITY 2 in the Main Menu it is easy to<br />
switch from one locality to another while working in the<br />
field. This procedure is particularly useful for measurement<br />
in two different depth levels in the same borehole.<br />
Measurement from one depth level can be associated with<br />
LOCALITY 1, from another depth level with LOCALITY 2.<br />
25<br />
*********** MAIN MENU **************<br />
LOCALITY 1 ABC<br />
LOCALITY 2<br />
LOCALITY MANAGEMENT<br />
CONTINUOUS MEASUREM.<br />
MONITOR<br />
COMMUNICATION<br />
SYSTEM CONFIGURATION<br />
CALIBRATION<br />
*********************************<br />
W. 9.1 - Main Menu after entering a new locality<br />
By selecting LOCALITY 1 ABC in the Main Menu you can start surveying the locality. (see Chapter 4 –<br />
Measurement - Standard Grid).<br />
3.12 SELECTING AN EXISTING LOCALITY<br />
If you have already measured a locality some time ago and you need to continue investigating it, select<br />
LOCALITY MANAGEMENT, then Open LOCALITY 1 (or Open LOCALITY 2) -- see Window W 4 -- and in the<br />
list of localities, select this locality – for example “XXX”. Its Configuration File will be opened which can either be<br />
changed or you can return without making any changes to the Main Menu by pressing ◄ and following the<br />
instructions on the screen. The selected locality is associated with LOCALITY 1 or with LOCALITY 2 and it can<br />
be measured by pressing the right arrow on LOCALITY 1 XXX (or LOCALITY 2 XXX) items in the Main Menu.