The above mentioned selection of the calibration gas and measured values are sufficient for a routine Soil<br />
Contamination Survey to provide a fast and cost effective identification of the relative concentration cloud,<br />
contaminant sources, migration routes and the size of the impacted area.<br />
Advanced<br />
In case the given Soil Contamination Survey task requires more precise evaluating (not standard), apply the<br />
following procedure:<br />
• Assume that the contaminant and soil characteristics are approximately homogeneous over the given<br />
environment.<br />
• Select the compound that characterizes the contaminant, from the list of measured compounds.<br />
• Select five holes for a comparative study. Compare the <strong>ECOPROBE</strong> 5 values from the five holes with<br />
laboratory analyzed samples from the same five holes.<br />
Note: The soil gas sampling procedure requires expertise and careful planning!<br />
• Determine the correlation coefficient for these samples. If the coefficient is approximately the same for<br />
all samples, use it to multiply the entire set of values from the measured locality to get semi-quantitative<br />
results.<br />
<strong>ECOPROBE</strong> 5’s PID analyzer has two ranges:<br />
PID ANALYZER<br />
HISENS – Lower detection limit is a few ppb; upper limit is 100 ppm. Output can be selected also in µg/m 3 .<br />
HISENS mode is extremely sensitive, suitable for measuring air contamination – near petrol pumps, etc. It is<br />
not suitable for measuring contamination of the ambient air. For Soil Contamination Survey tasks it is<br />
necessary to thoroughly observe the methodology of field measuring (cleaning procedures, etc.) since facto<strong>rs</strong><br />
like moisture, presence of methane or under-pressure may influence the results. HISENS mode enables you<br />
to measure even cutting and transformer oils in a subsurface environment, if the proper measuring procedure<br />
is followed.<br />
STANDARD – Lower detection limit is 0.1 ppm; upper limit varies from 2000 to 4000 ppm depending on the<br />
measured compound (output also in mg/ m3).<br />
Application of <strong>ECOPROBE</strong> 5’s PID Analyzer<br />
1. For measuring small values of contaminant concentration.<br />
2. For measuring a wide spectrum of contaminants.<br />
3. For quantitative measurements.<br />
60