DATA INTERPRETATION<br />
Railway Station 14. 6. 2000<br />
Fig. 28<br />
74<br />
CASE STUDY 3 (Fig. 28)<br />
PID measurements made at the<br />
railway station shows the largest<br />
hydrocarbon contamination from 40 to<br />
95 m along all profiles. Several small<br />
contaminated domains in the<br />
surveyed area, are confirmed by the<br />
IR TP analyzer (see the third graph)<br />
Methane channel shows relatively<br />
high concentrations of methane,<br />
which is characteristic of old<br />
contamination where bacterial activity<br />
has already started.<br />
At the position of the main<br />
contamination, the TP channel shows<br />
higher values than the methane<br />
channel. This indicates the presence<br />
of hydrocarbon contamination. There<br />
is also an indication on the TP<br />
channel at 100 –110 m on the profiles<br />
95 and 100, of fresh hydrocarbon<br />
contamination. No methane is<br />
present.<br />
Bacterial activity is expressed by high<br />
concentrations of CO2 at the position<br />
of the main contaminated area<br />
(compare also with the PID channel).