AKD <strong>Installation</strong> | 8 Electrical <strong>Installation</strong>8.14.8 Sine Encoder with Hall EncoderFeedback devices, which do not deliver absolute information for commutation, can be used as a completefeedback system when combined with an additional Hall encoder. All signals are connected to X10 and evaluatedthere. If cable lengths of more than 25 m are planned, please consult customer support. The "Sense" signalis optional, and can be omitted if the encoder cable is short and no significant voltage drop is on the cable.The voltage drop depends on the cable length and gage and the encoder current consumption.Type FBTYPE Up Frequency Limit (sin, cos)SinCos 5 V with Hall 20 5 V +/-5% 1 MHzKollmorgen | December 2009 105