AKD <strong>Installation</strong> | 8 Electrical <strong>Installation</strong>8.11.3 Shielding Connection to the DriveYou can connect cable shielding directly to the drive by using grounding plates, shield connection clamps, anda motor connector with strain relief and grounding plate.8.11.3.1 Grounding PlatesMount the grounding plates to the drive as shown in the photos below.AKD-x0306 to x1206 types:L-shape grounding plateAKD-x02406 & xxx07 types:flat grounding plate8.11.3.2 Shield connection clampsUse shield connection clamps (see accessories manual). These hook into thegrounding plate and ensure optimum contact between the shield and the groundingplate.Kollmorgen recommends using Phoenix Contact SK14 shield clamps with clamprange of 6-13mm.84 Kollmorgen | December 2009