AKD <strong>Installation</strong> | 6 Technical description and data6.16.3 Implementation of the Stop Category 0Bringing the motor to a standstill by immediately switching off the drive power supply (DRV.DISMODE mustbe set to 2). The switching sequence is precisely determined by this circuit in order to avoid undesirable faultmessages and drive failures.It is not possible to achieve a Category 0 shut-down with the drive alone, since hard-wired electromechanicalcomponents are compulsory for this type of disconnection.A brake that is built into the motor must have an additional electromechanical control circuit, as well as thecontrol through the AKD, in order to meet Category 0.In most servomotors a brake has only the function of a holding brake. To ensure an emergency stop function,the braking torque that is required must be checked. If the holding brake fulfills the dynamic requirements, itmust be taken into account that this application will cause increased wear.Circuit suggestion (with EMERGENCY STOP Category 0, control function with contactor relays)Kollmorgen | December 2009 51