AKD <strong>Installation</strong> | 6 Technical description and data6.10 ConnectorsGiven voltage and current data are the lowest values allowed by UL and CE. Order codes see page 1446.10.1 AKD-xxxx06 Types (120V to 240V Mains Voltage Supply)Connector Type Max. Cross Section1AllowedCurrent 2AllowedVoltage 3Control signals X7, X8 Weidmüller BL3.5/10F SN 1.5 mm², 16 awg 10 A 250 VAux. voltage X1 Phoenix, MC1.5/3-STF-3.81 1.5 mm², 16 awg 8 A 160 VMotor X2 (3 to 6 A) Phoenix, IC 2.5/6-STF-5.08 2.5 mm², 14 awg 10 A 300 VMotor X2 (12 to 24A) Phoenix, PC 5/6-STF-7.62 10 mm², 10 awg 30 A 600 VPower X3 (3 to 6A) Phoenix, MVSTBW2.5/7-STF-5.08 2.5 mm², 12 awg 10 A 300 VPower X3 (12A) Phoenix, MSTB2,5HC/8-STF-5,08 2,5 mm², 12 awg 16 A 300 VPower X3 (24A) Phoenix, PC 5/4-STF-7,62 10 mm², 10 awg 30 A 600 VPower X4 (24A) Phoenix, PC 5/4-STF-7,62 10 mm², 10 awg 30 A 600 VFeedback X10 SubD 15pin HD (female) 0,5 mm², 21 awg 1 A