Additional requirements for licensed<strong>asbestos</strong> removal259. The licensed removalist must ensure that only persons perform<strong>in</strong>g <strong>asbestos</strong>removal work, persons engaged <strong>in</strong> work <strong>in</strong>cidental to the removal work whorequire access (eg an occupational hygienist) and persons with a statutory right(eg members of <strong>Victoria</strong> Police and <strong>WorkSafe</strong> <strong>in</strong>spectors) have access to theremoval area.260. Reliance on signs and barricades alone to deny unauthorised access to theremoval area is not sufficient. The licensed removalist’s system of work needsto <strong>in</strong>clude regular check<strong>in</strong>g of areas where access is possible. In some cases,such check<strong>in</strong>g may need to be cont<strong>in</strong>uous.261. All barriers and warn<strong>in</strong>g signs must rema<strong>in</strong> <strong>in</strong> place until a clearance tore-occupy the site has been granted (refer to ‘Clearance to re-occupy as<strong>asbestos</strong> removal area’ on page 68).The decontam<strong>in</strong>ation unit262. Decontam<strong>in</strong>ation units are generally required for all friable <strong>asbestos</strong> removaljobs other than ‘wrap and cut’, ‘glove bag’ and gasket removals. Non-friable<strong>asbestos</strong> removal jobs of a certa<strong>in</strong> size (eg where the ACM to be removedis greater than that conta<strong>in</strong>ed <strong>in</strong> the cladd<strong>in</strong>g of an average size house) mayalso require the use of decontam<strong>in</strong>ation units. A risk assessment needs tobe conducted to determ<strong>in</strong>e this while also tak<strong>in</strong>g <strong>in</strong>to account the:• condition of the ACM• difficulty <strong>in</strong> perform<strong>in</strong>g the removal• level of airborne dust likely to be generated• available clean<strong>in</strong>g/wash<strong>in</strong>g facilities at the site• duration of the task.263. Where men and women are required to use the same decontam<strong>in</strong>ation unit,a system of work needs be implemented to enable them to access the unitseparately.264. In many <strong>in</strong>stances, the only satisfactory way of provid<strong>in</strong>g appropriate chang<strong>in</strong>gfacilities is to provide a mobile or specially constructed on-site decontam<strong>in</strong>ationunit.265. This decontam<strong>in</strong>ation unit needs be immediately adjacent to and directlyconnected with the enclosed <strong>asbestos</strong> work area. It needs to be locatedas far away as practicable from amenities and lunch rooms.266. The decontam<strong>in</strong>ation unit needs to be divided <strong>in</strong>to three dist<strong>in</strong>ct areas:• dirty decontam<strong>in</strong>ation area• clean decontam<strong>in</strong>ation area• clean chang<strong>in</strong>g area.267. All of these areas need be large enough to enable employees to adequatelydecontam<strong>in</strong>ate themselves.268. These areas need to be separated by suitable airlocks or buffer zones. Normallythese airlocks have spr<strong>in</strong>g-loaded doors or two or more overlapp<strong>in</strong>g sheets ofplastic sheet that are positioned to def<strong>in</strong>e the boundary between each segmentof the decontam<strong>in</strong>ation unit while allow<strong>in</strong>g access and airflow towards the<strong>asbestos</strong> work area. To ensure there is sufficient airflow through thedecontam<strong>in</strong>ation unit, doors (if used) need to have large open<strong>in</strong>gs with a h<strong>in</strong>gedflap operat<strong>in</strong>g as a one-way valve. See Figure 8 on page 50 for a typical layout.<strong>WorkSafe</strong> <strong>Victoria</strong> <strong>Compliance</strong> code / <strong>Remov<strong>in</strong>g</strong> <strong>asbestos</strong> <strong>in</strong> <strong>workplaces</strong> 49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!